1 #!/bin/sh - 2 # 3 # $NetBSD: sensor_battery,v 1.7 2010/02/15 22:56:13 pgoyette Exp $ 4 # 5 # Generic script for battery sensors. 6 # 7 # Arguments passed by powerd(8): 8 # 9 # script_path device event sensor state_description 10 # 11 case "${2}" in 12 normal) 13 logger -p warning \ 14 "${0}: (${3}) capacity reached normal state [${1}]" >&1 15 exit 0 16 ;; 17 state-changed) 18 logger -p warning "${0}: (${3}) state changed to ${4} [${1}]" >&1 19 exit 0 20 ;; 21 warning-capacity) 22 logger -p warning \ 23 "${0}: (${3}) capacity below warning limit [${1}]" >&1 24 exit 0 25 ;; 26 critical-capacity) 27 logger -p warning \ 28 "${0}: (${3}) capacity below critical limit [${1}]" >&1 29 exit 0 30 ;; 31 high-capacity) 32 logger -p warning \ 33 "${0}: (${3}) capacity above high limit [${1}]" >&1 34 exit 0 35 ;; 36 maximum-capacity) 37 logger -p warning \ 38 "${0}: (${3}) capacity above maximum limit [${1}]" >&1 39 exit 0 40 ;; 41 # 42 # This event is _ONLY_ received when all AC Adapters are OFF and all 43 # batteries on the system are in CRITICAL or LOW state. 44 # 45 # It is not recommended to remove the shutdown call. 46 # 47 low-power) 48 logger -p warning "${0}: LOW POWER! SHUTTING DOWN." >&1 49 /sbin/shutdown -p now "${0}: LOW POWER! SHUTTING DOWN." 50 exit 0 51 ;; 52 *) 53 logger -p warning "${0}: unsupported event ${2} on device ${1}" >&1 54 exit 1 55 ;; 56 esac 57