DISKLESS revision 1.21 1 # $NetBSD: DISKLESS,v 1.21 2005/07/07 17:05:58 tron Exp $
2
3 # DISKLESS Sun2 (2/120, 2/170, 2/50, ...)
4 # Supports root on: ie0, ec0
5
6 include "arch/sun2/conf/std.sun2"
7
8 #options INCLUDE_CONFIG_FILE # embed config file in kernel binary
9
10 #ident "DISKLESS-$Revision: 1.21 $"
11
12 # Machines to be supported by this kernel
13 #options FPU_EMULATE
14
15 # Needs to be set per system. i.e change these as you see fit
16 maxusers 8
17
18 # Standard system options
19 options KTRACE # system call tracing
20 options SYSVMSG # System V message queues
21 options SYSVSEM # System V semaphores
22 options SYSVSHM # System V shared memory
23 #options SHMMAXPGS=1024 # 1024 pages is the default
24 #options LKM # loadable kernel modules
25 #options INSECURE # disable kernel security level
26 options USERCONF # userconf(4) support
27 #options PIPE_SOCKETPAIR # smaller, but slower pipe(2)
28 #options SYSCTL_INCLUDE_DESCR # Include sysctl descriptions in kernel
29 #options MALLOC_NOINLINE # Not inlining MALLOC saves memory
30
31 # Which kernel debugger? Uncomment either this:
32 options DDB
33 # ... or these for KGDB (gdb remote target)
34 #makeoptions DEBUG="-g" # debugging symbols for gdb
35 #options KGDB
36 #options KGDB_DEV=0x0C00 # ttya=0C00 ttyb=0C01
37
38 # Other debugging options
39 #options DDB_HISTORY_SIZE=100 # enable history editing in DDB
40 #options DEBUG # kernel debugging code
41 #options DIAGNOSTIC # extra kernel sanity checking
42 #options KMEMSTATS # kernel memory statistics (vmstat -m)
43 #options PMAP_DEBUG
44 #options SCSIDEBUG
45 #options SCSIVERBOSE # Verbose SCSI errors
46
47 # Compatibility options
48 #options COMPAT_SUNOS # can run SunOS 4.1.1 executables
49 options COMPAT_43 # and 4.3BSD and ...
50 #options COMPAT_AOUT_M68K # support for NetBSD a.out executables
51 options COMPAT_16
52 options COMPAT_20
53 #options TCP_COMPAT_42 # 4.2BSD TCP/IP bug compat. Not recommended.
54 options EXEC_AOUT # support for a.out executables
55 options COMPAT_BSDPTY # /dev/[pt]ty?? ptys.
56
57 # Filesystem options
58 #file-system FFS # Berkeley Fast Filesystem
59 file-system NFS # Sun NFS client support
60 #file-system CD9660 # ISO 9660 + Rock Ridge file system
61 file-system FDESC # /dev/fd/*
62 file-system KERNFS # /kern
63 file-system NULLFS # loopback file system
64 file-system OVERLAY # overlay file system
65 #file-system PROCFS # /proc
66 file-system UNION # union file system
67 file-system MFS # memory-based filesystem
68
69 #options NFSSERVER # nfs server support
70 #options QUOTA # FFS quotas
71 #options FFS_EI # FFS Endian Independant support
72 #options SOFTDEP # FFS soft updates support.
73 #options NFS_V2_ONLY # Exclude NFS3 and NQNFS code to save space
74 options VNODE_OP_NOINLINE # Not inlining vnode op calls saves mem
75
76 # Networking options
77 options INET # IP prototol stack support
78 #options INET6 # IPV6
79 #options IPSEC # IP security
80 #options IPSEC_ESP # IP security (encryption part; define w/IPSEC)
81 #options IPSEC_NAT_T # IPsec NAT traversal (NAT-T)
82 #options IPSEC_DEBUG # debug for IP security
83 #options GATEWAY # IP packet forwarding
84 #options ISO,TPIP # OSI networking
85 #options EON # OSI tunneling over IP
86 #options CCITT,LLC,HDLC # X.25
87 options PFIL_HOOKS # pfil(9) packet filter hooks.
88 #options TCP_DEBUG # Record last TCP_NDEBUG packets with SO_DEBUG
89
90 # Work-around for root on slow servers (insurance...)
91 options NFS_BOOT_RWSIZE=1024
92 options NFS_BOOT_BOOTPARAM
93
94 config netbsd root on ? type ?
95
96 #### Main bus.
97 mainbus0 at root
98
99 #### Bus types.
100
101 obio0 at mainbus? # all Sun-2
102 obmem0 at mainbus? # all Sun-2
103 mbmem0 at mainbus? # 2/120, 2/170
104 mbio0 at mainbus? # 2/120, 2/170
105 sun68kvme0 at mainbus? # 2/50, 2/130, 2/160
106 vme0 at sun68kvme0 # mi VME attachment
107
108 #### Standard system devices.
109
110 ## The AM9513 clock chip.
111 clock0 at obio0 addr 0x002800 # 2/120, 2/170
112 clock0 at obio0 addr 0x7f2800 # 2/50, 2/130, 2/160
113
114 ## The MM58167 time-of-day chip.
115 tod0 at obio0 addr 0x003800 # 2/120, 2/170
116 tod0 at vme0 addr 0x200800 # 2/50, 2/130, 2/160
117
118 #### Serial port configuration.
119
120 ## Zilog 8530 serial chips. Each has two channels.
121 ## zs0 is ttya and ttyb. zs1 is the keyboard and mouse.
122 ## zs0 is REQUIRED to use KGDB.
123 zs0 at obio0 addr 0x002000 # 2/120, 2/170
124 zs0 at obio0 addr 0x7f2000 # 2/50
125 zs1 at obmem0 addr 0x780000 # 2/120, 2/170
126 zs1 at obio0 addr 0x7f1800 # 2/50
127 #zs2 at mbmem0 addr 0x080800 # 2/120, 2/170 (first sc SCSI)
128 #zs3 at mbmem0 addr 0x081000 # 2/120, 2/170 (first sc SCSI)
129 #zs4 at mbmem0 addr 0x084800 # 2/120, 2/170 (second sc SCSI)
130 #zs5 at mbmem0 addr 0x085000 # 2/120, 2/170 (second sc SCSI)
131 zstty* at zs? channel ? # ttya
132 kbd0 at zstty? # keyboard
133 ms0 at zstty? # mouse
134
135 #### Disk controllers and disks.
136
137 ## PAL+logic-based "Sun SCSI 2" Multibus/VME SCSI controller.
138 ## This driver has several flags which may be enabled using
139 ## the "flags" directive. Valid flags are:
140 ##
141 ## 0x0ff Set (1<<target) to disable parity checking
142 ## 0x100 Set this bit to disable DMA interrupts (poll)
143 ## 0x200 Set this bit to disable DMA entirely (use PIO)
144 ##
145 ## For example: "flags 0x10f" would disable DMA interrupts,
146 ## and disable parity for targets 0-3
147
148 #sc0 at mbmem0 addr 0x80000 ipl 2 flags 0xff
149 #sc0 at vme0 addr 0x200000 irq 2 vect 0x40 flags 0xff
150 #sc1 at mbmem0 addr 0x84000 ipl 2 flags 0xff
151
152 ## NCR5380-based "Sun SCSI 3" VME SCSI controller.
153 ## This driver has several flags which may be enabled by OR'ing
154 ## the values and using the "flags" directive.
155 ## Valid flags are:
156 ##
157 ## 0x01 Use DMA (may be polled)
158 ## 0x02 Use DMA completion interrupts
159 ## 0x04 Allow disconnect/reselect
160 ##
161 ## E.g. the following would enable DMA, interrupts, and reselect:
162 ## si0 at vme0 addr 0x200000 ipl 3 vect 0x40 flags 0x07
163 ##
164 ## By default, DMA is enabled in the driver.
165
166 #si0 at vme0 addr 0x200000 irq 2 vect 0x40
167
168 ## These entries find devices on all SCSI busses and assign
169 ## unit numbers dynamically.
170 #scsibus* at sc?
171 #scsibus* at si?
172 #sd* at scsibus? target ? lun ? # SCSI disks
173 #st* at scsibus? target ? lun ? # SCSI tapes
174 #cd* at scsibus? target ? lun ? # SCSI CD-ROMs
175 #ch* at scsibus? target ? lun ? # SCSI changer devices
176 #ss* at scsibus? target ? lun ? # SCSI scanners
177 #ses* at scsibus? target ? lun ? # SCSI SES/SAF-TE
178 #uk* at scsibus? target ? lun ? # unknown SCSI
179
180 # support old SCSI devices that don't understand the INQUIRY command
181 #options SCSI_OLD_NOINQUIRY
182
183 ## Xylogics 450 or 451 Multibus/VME SMD disk controllers and disks.
184 #xyc0 at mbio0 addr 0xee40 ipl 2
185 #xyc0 at vme0 addr 0xee40 irq 2 vect 0x48
186 #xyc1 at mbio0 addr 0xee48 ipl 2
187 #xyc1 at vme0 addr 0xee48 irq 2 vect 0x49
188 #xy* at xyc? drive ?
189
190 ## Memory-disk device.
191 pseudo-device md 2
192
193 #### Network interfaces.
194
195 ## Intel Ethernet (onboard, or Multibus/VME)
196 ie0 at obio0 addr 0x7f0800 ipl 3 # 2/50
197 ie0 at mbmem0 addr 0x88000 ipl 3
198 ie1 at mbmem0 addr 0x8c000 ipl 3
199 ## VME: the first [addr,len] pair specifies the device registers;
200 ## the second pair specifies the on-board memory buffer
201 ie1 at vme0 addr 0xe88000,0xe00000 len -1,0x40000 irq 3 vect 0x75
202
203 ## 3Com Ethernet (Multibus only)
204 ec0 at mbmem0 addr 0xe0000 ipl 3
205 ec1 at mbmem0 addr 0xe2000 ipl 3
206
207 ## Frame buffers.
208
209 ## Sun "bwtwo" black and white framebuffer.
210 bwtwo0 at obmem0 addr 0x700000 # 2/120, 2/170
211 bwtwo0 at obio0 addr 0x0 # 2/50
212
213 ## PROM console driver -- if all else fails
214 pcons0 at mainbus0 # PROM console
215
216 #### Miscellaneous.
217 pseudo-device loop 1 # network loopback
218 #pseudo-device bpfilter 8 # packet filter
219 #pseudo-device sl 2 # CSLIP
220 #pseudo-device ppp 2 # PPP
221 #pseudo-device tun 2 # network tunneling over tty
222 #pseudo-device gre 2 # generic L3 over IP tunnel
223 #pseudo-device ipfilter # ip filter
224 #pseudo-device gif 4 # IPv[46] over IPv[46] tunnel (RFC1933)
225 #pseudo-device faith 1 # IPv[46] tcp relay translation i/f
226 #pseudo-device stf 1 # 6to4 IPv6 over IPv4 encapsulation
227 # rnd is EXPERIMENTAL
228 #pseudo-device rnd # /dev/random and in-kernel generator
229
230 pseudo-device pty 32 # pseudo-terminals
231 #pseudo-device vnd 4 # paging to files
232 #pseudo-device ccd 4 # concatenated disks
233 #pseudo-device raid 4 # RAIDframe disk driver
234 #options RAID_AUTOCONFIG # auto-configuration of RAID components
235 #pseudo-device fss 4 # file system snapshot device
236
237 pseudo-device clockctl # user control of clock subsystem
238