INSTALL revision 1.7
11.7Sfredette# $NetBSD: INSTALL,v 1.7 2001/11/26 17:51:08 fredette Exp $
21.1Sfredette
31.1Sfredette# INSTALL Sun2 (2/120, 2/170, 2/50, ...)
41.1Sfredette
51.1Sfredetteinclude "arch/sun2/conf/std.sun2"
61.1Sfredette
71.7Sfredette#ident 		"INSTALL-$Revision: 1.7 $"
81.1Sfredette
91.1Sfredette# Machines to be supported by this kernel
101.1Sfredette#options 	FPU_EMULATE
111.1Sfredette
121.1Sfredette# Needs to be set per system.  i.e change these as you see fit
131.1Sfredettemaxusers	2
141.1Sfredette
151.1Sfredette# Standard system options
161.1Sfredette#options 	KTRACE		# system call tracing
171.1Sfredette#options 	SYSVMSG		# System V message queues
181.1Sfredette#options 	SYSVSEM		# System V semaphores
191.1Sfredette#options 	SYSVSHM		# System V shared memory
201.1Sfredette#options 	SHMMAXPGS=1024	# 1024 pages is the default
211.1Sfredette#options 	LKM		# loadable kernel modules
221.1Sfredette#options 	INSECURE	# disable kernel security level
231.1Sfredette#options 	UCONSOLE	# Allow non-root TIOCCONS
241.1Sfredette
251.1Sfredette# Which kernel debugger?  Uncomment either this:
261.1Sfredette#options 	DDB
271.1Sfredette# ... or these for KGDB (gdb remote target)
281.6Slukem#makeoptions	DEBUG="-g"	# debugging symbols for gdb
291.1Sfredette#options 	KGDB
301.5Slukem#options 	KGDB_DEV=0x0C00	# ttya=0C00 ttyb=0C01
311.1Sfredette
321.1Sfredette# Other debugging options
331.1Sfredette#options 	DDB_HISTORY_SIZE=100	# enable history editing in DDB
341.1Sfredette#options 	DEBUG		# kernel debugging code
351.1Sfredette#options 	DIAGNOSTIC	# extra kernel sanity checking
361.1Sfredette#options 	KMEMSTATS	# kernel memory statistics (vmstat -m)
371.1Sfredette#options 	PMAP_DEBUG
381.1Sfredette#options 	SCSIDEBUG
391.1Sfredette#options 	SCSIVERBOSE		# Verbose SCSI errors
401.1Sfredette
411.2Swiz# Compatibility options
421.1Sfredette#options 	COMPAT_SUNOS	# can run SunOS 4.1.1 executables
431.1Sfredette#options 	COMPAT_43	# and 4.3BSD and ...
441.7Sfredette#options 	COMPAT_AOUT_M68K # support for NetBSD a.out executables
451.7Sfredette#options 	TCP_COMPAT_42	# 4.2BSD TCP/IP bug compat. Not recommended.
461.6Slukemoptions 	EXEC_AOUT	# support for a.out executables
471.1Sfredette
481.1Sfredette# Filesystem options
491.1Sfredettefile-system	FFS		# Berkeley Fast Filesystem
501.1Sfredettefile-system	NFS		# Sun NFS client support
511.1Sfredettefile-system	CD9660		# ISO 9660 + Rock Ridge file system
521.1Sfredette#file-system	FDESC		# /dev/fd/*
531.1Sfredette#file-system	KERNFS		# /kern
541.1Sfredette#file-system	NULLFS		# loopback file system
551.1Sfredette#file-system	OVERLAY		# overlay file system
561.1Sfredette#file-system	PROCFS		# /proc
571.1Sfredette#file-system	UNION		# union file system
581.1Sfredette#file-system	MFS		# memory-based filesystem
591.1Sfredette
601.1Sfredette#options 	NFSSERVER	# nfs server support
611.1Sfredette#options 	QUOTA		# FFS quotas
621.1Sfredette#options 	FFS_EI		# FFS Endian Independant support
631.6Slukem#options 	SOFTDEP		# FFS soft updates support.
641.1Sfredette
651.1Sfredette# Networking options
661.1Sfredetteoptions 	INET		# IP prototol stack support
671.1Sfredette#options 	INET6		# IPV6
681.1Sfredette#options 	IPSEC		# IP security
691.1Sfredette#options 	IPSEC_ESP	# IP security (encryption part; define w/IPSEC)
701.1Sfredette#options 	IPSEC_DEBUG	# debug for IP security
711.1Sfredette#options 	GATEWAY		# IP packet forwarding
721.1Sfredette#options 	ISO,TPIP	# OSI networking
731.1Sfredette#options 	EON		# OSI tunneling over IP
741.1Sfredette#options 	CCITT,LLC,HDLC	# X.25
751.1Sfredette#options 	PFIL_HOOKS	# pfil(9) packet filter hooks.
761.4Sabs#options 	TCP_DEBUG	# Record last TCP_NDEBUG packets with SO_DEBUG
771.1Sfredette
781.1Sfredette# Work-around for root on slow servers (insurance...)
791.1Sfredetteoptions 	NFS_BOOT_RWSIZE=1024
801.1Sfredetteoptions 	NFS_BOOT_BOOTPARAM
811.1Sfredette
821.1Sfredetteconfig		netbsd root on ? type ?
831.1Sfredette
841.1Sfredette#### Main bus.
851.1Sfredettemainbus0 at root
861.1Sfredette
871.1Sfredette#### Bus types.
881.1Sfredette
891.1Sfredetteobio0	at mainbus? 		# all Sun-2
901.1Sfredetteobmem0	at mainbus?		# all Sun-2
911.1Sfredettembmem0	at mainbus?		# 2/120, 2/170
921.1Sfredettembio0	at mainbus?		# 2/120, 2/170
931.3Sfredettesun68kvme0	at mainbus?	# 2/50, 2/130, 2/160
941.3Sfredettevme0	at sun68kvme0		# mi VME attachment
951.1Sfredette
961.1Sfredette#### Standard system devices.
971.1Sfredette
981.1Sfredette## The AM9513 clock chip.
991.6Slukemclock0	at obio0 addr 0x002800	# 2/120, 2/170
1001.6Slukemclock0	at obio0 addr 0x7f2800	# 2/50, 2/130, 2/160
1011.1Sfredette
1021.1Sfredette## The MM58167 time-of-day chip.
1031.6Slukemtod0	at obio0 addr 0x003800	# 2/120, 2/170
1041.3Sfredettetod0	at vme0 addr 0x200800	# 2/50, 2/130, 2/160
1051.1Sfredette
1061.1Sfredette#### Serial port configuration.
1071.1Sfredette
1081.3Sfredette## Zilog 8530 serial chips.  Each has two channels.
1091.1Sfredette## zs0 is ttya and ttyb.  zs1 is the keyboard and mouse.
1101.1Sfredette## zs0 is REQUIRED to use KGDB.
1111.1Sfredettezs0	at obio0 addr 0x002000	# 2/120, 2/170
1121.3Sfredettezs0	at obio0 addr 0x7f2000	# 2/50
1131.1Sfredettezs1	at obmem0 addr 0x780000	# 2/120, 2/170
1141.3Sfredettezs1	at obio0 addr 0x7f1800	# 2/50
1151.1Sfredettezs2	at mbmem0 addr 0x080800	# 2/120, 2/170 (first sc SCSI)
1161.1Sfredettezs3	at mbmem0 addr 0x081000	# 2/120, 2/170 (first sc SCSI)
1171.1Sfredettezs4	at mbmem0 addr 0x084800	# 2/120, 2/170 (second sc SCSI)
1181.1Sfredettezs5	at mbmem0 addr 0x085000	# 2/120, 2/170 (second sc SCSI)
1191.3Sfredettezstty*	at zs? channel ?	# ttya
1201.3Sfredettekbd0	at zstty?		# keyboard
1211.3Sfredette#ms0	at zstty?		# mouse
1221.1Sfredette
1231.1Sfredette#### Disk controllers and disks.
1241.1Sfredette
1251.1Sfredette## PAL+logic-based "Sun SCSI 2" Multibus/VME SCSI controller.
1261.1Sfredette## This driver has several flags which may be enabled using
1271.1Sfredette## the "flags" directive.  Valid flags are:
1281.1Sfredette##
1291.1Sfredette## 0x0ff		Set (1<<target) to disable parity checking
1301.1Sfredette## 0x100		Set this bit to disable DMA interrupts (poll)
1311.1Sfredette## 0x200		Set this bit to disable DMA entirely (use PIO)
1321.1Sfredette##
1331.1Sfredette## For example: "flags 0x10f" would disable DMA interrupts,
1341.1Sfredette## and disable parity for targets 0-3
1351.1Sfredette
1361.1Sfredettesc0	at mbmem0 addr 0x80000 ipl 2 flags 0xff
1371.6Slukemsc0	at vme0 addr 0x200000 irq 2 vect 0x40 flags 0xff
1381.1Sfredettesc1	at mbmem0 addr 0x84000 ipl 2 flags 0xff
1391.1Sfredette
1401.1Sfredette## NCR5380-based "Sun SCSI 3" VME SCSI controller.
1411.1Sfredette## This driver has several flags which may be enabled by OR'ing
1421.1Sfredette## the values and using the "flags" directive.
1431.1Sfredette## Valid flags are:
1441.1Sfredette##
1451.1Sfredette##	0x01		Use DMA (may be polled)
1461.1Sfredette##	0x02		Use DMA completion interrupts
1471.1Sfredette##	0x04		Allow disconnect/reselect
1481.1Sfredette##
1491.1Sfredette## E.g. the following would enable DMA, interrupts, and reselect:
1501.1Sfredette## si0	at vme0 addr 0x200000 ipl 3 vect 0x40 flags 0x07
1511.1Sfredette##
1521.1Sfredette## By default, DMA is enabled in the driver.
1531.1Sfredette
1541.3Sfredettesi0	at vme0 addr 0x200000 irq 2 vect 0x40
1551.1Sfredette
1561.1Sfredette## These entries find devices on all SCSI busses and assign
1571.1Sfredette## unit numbers dynamically.
1581.1Sfredettescsibus* at sc?
1591.3Sfredettescsibus* at si?
1601.1Sfredettesd*	at scsibus? target ? lun ?		# SCSI disks
1611.1Sfredettest*	at scsibus? target ? lun ?		# SCSI tapes
1621.1Sfredettecd*	at scsibus? target ? lun ?		# SCSI CD-ROMs
1631.1Sfredette#ch*	at scsibus? target ? lun ?		# SCSI changer devices
1641.1Sfredette#ss*	at scsibus? target ? lun ?		# SCSI scanners
1651.1Sfredette#ses*	at scsibus? target ? lun ?		# SCSI SES/SAF-TE
1661.1Sfredette#uk*	at scsibus? target ? lun ?		# unknown SCSI
1671.1Sfredette
1681.1Sfredette## Xylogics 450 or 451 Multibus/VME SMD disk controllers and disks.
1691.6Slukem#xyc0	at mbio0 addr 0xee40 ipl 2
1701.3Sfredettexyc0	at vme0 addr 0xee40 irq 2 vect 0x48
1711.6Slukem#xyc1	at mbio0 addr 0xee48 ipl 2
1721.3Sfredettexyc1	at vme0 addr 0xee48 irq 2 vect 0x49
1731.3Sfredettexy*	at xyc? drive ?
1741.1Sfredette
1751.1Sfredette## Memory-disk device.
1761.1Sfredette#pseudo-device	md		2
1771.1Sfredette
1781.1Sfredette#### Network interfaces.
1791.1Sfredette
1801.1Sfredette## Intel Ethernet (onboard, or Multibus/VME)
1811.3Sfredetteie0	at obio0 addr 0x7f0800 ipl 3		# 2/50
1821.1Sfredetteie0	at mbmem0 addr 0x88000 ipl 3
1831.3Sfredetteie1	at mbmem0 addr 0x8c000 ipl 3
1841.3Sfredette## VME: the first [addr,len] pair specifies the device registers;
1851.3Sfredette##	the second pair specifies the on-board memory buffer
1861.3Sfredetteie1	at vme0 addr 0xe88000,0xe00000 len -1,0x40000 irq 3 vect 0x75
1871.3Sfredette
1881.3Sfredette## 3Com Ethernet (Multibus only)
1891.3Sfredetteec0	at mbmem0 addr 0xe0000 ipl 3
1901.3Sfredetteec1	at mbmem0 addr 0xe2000 ipl 3
1911.1Sfredette
1921.1Sfredette## Frame buffers.
1931.1Sfredette
1941.1Sfredette## Sun "bwtwo" black and white framebuffer.
1951.6Slukembwtwo0	at obmem0 addr 0x700000	# 2/120, 2/170
1961.3Sfredettebwtwo0	at obio0 addr 0x0	# 2/50
1971.3Sfredette
1981.3Sfredette## PROM console driver -- if all else fails
1991.3Sfredettepcons0	at mainbus0			# PROM console
2001.1Sfredette
2011.1Sfredette#### Miscellaneous.
2021.1Sfredettepseudo-device	loop		1	# network loopback
2031.1Sfredette#pseudo-device	bpfilter	8	# packet filter
2041.1Sfredette#pseudo-device	sl		2	# CSLIP
2051.1Sfredette#pseudo-device	ppp		2	# PPP
2061.1Sfredette#pseudo-device	tun		2	# network tunneling over tty
2071.1Sfredette#pseudo-device	gre		2	# generic L3 over IP tunnel
2081.1Sfredette#pseudo-device	ipfilter		# ip filter
2091.1Sfredette#pseudo-device	gif		4	# IPv[46] over IPv[46] tunnel (RFC1933)
2101.1Sfredette#pseudo-device	faith		1	# IPv[46] tcp relay translation i/f
2111.1Sfredette#pseudo-device	stf		1	# 6to4 IPv6 over IPv4 encapsulation
2121.1Sfredette# rnd is EXPERIMENTAL
2131.1Sfredette#pseudo-device	rnd			# /dev/random and in-kernel generator
2141.1Sfredette
2151.1Sfredettepseudo-device	pty		4	# pseudo-terminals
2161.1Sfredette#pseudo-device	vnd		4	# paging to files
2171.1Sfredette#pseudo-device	ccd		4	# concatenated disks
2181.1Sfredette#pseudo-device	raid		4	# RAIDframe disk driver
2191.1Sfredette#options 	RAID_AUTOCONFIG		# auto-configuration of RAID components
220