INSTALL revision 1.9 1 # $NetBSD: INSTALL,v 1.9 2001/12/15 22:22:13 fredette Exp $
2
3 # INSTALL Sun2 (2/120, 2/170, 2/50, ...)
4
5 include "arch/sun2/conf/std.sun2"
6
7 #ident "INSTALL-$Revision: 1.9 $"
8
9 # Machines to be supported by this kernel
10 #options FPU_EMULATE
11
12 # Needs to be set per system. i.e change these as you see fit
13 maxusers 2
14
15 # Standard system options
16 #options KTRACE # system call tracing
17 #options SYSVMSG # System V message queues
18 #options SYSVSEM # System V semaphores
19 #options SYSVSHM # System V shared memory
20 #options SHMMAXPGS=1024 # 1024 pages is the default
21 #options LKM # loadable kernel modules
22 #options INSECURE # disable kernel security level
23 #options UCONSOLE # Allow non-root TIOCCONS
24
25 # Which kernel debugger? Uncomment either this:
26 #options DDB
27 # ... or these for KGDB (gdb remote target)
28 #makeoptions DEBUG="-g" # debugging symbols for gdb
29 #options KGDB
30 #options KGDB_DEV=0x0C00 # ttya=0C00 ttyb=0C01
31
32 # Other debugging options
33 #options DDB_HISTORY_SIZE=100 # enable history editing in DDB
34 #options DEBUG # kernel debugging code
35 #options DIAGNOSTIC # extra kernel sanity checking
36 #options KMEMSTATS # kernel memory statistics (vmstat -m)
37 #options PMAP_DEBUG
38 #options SCSIDEBUG
39 #options SCSIVERBOSE # Verbose SCSI errors
40
41 # Compatibility options
42 #options COMPAT_SUNOS # can run SunOS 4.1.1 executables
43 #options COMPAT_43 # and 4.3BSD and ...
44 #options COMPAT_AOUT_M68K # support for NetBSD a.out executables
45 #options TCP_COMPAT_42 # 4.2BSD TCP/IP bug compat. Not recommended.
46 options EXEC_AOUT # support for a.out executables
47
48 # Filesystem options
49 file-system FFS # Berkeley Fast Filesystem
50 file-system NFS # Sun NFS client support
51 file-system CD9660 # ISO 9660 + Rock Ridge file system
52 #file-system FDESC # /dev/fd/*
53 file-system KERNFS # /kern
54 #file-system NULLFS # loopback file system
55 #file-system OVERLAY # overlay file system
56 #file-system PROCFS # /proc
57 #file-system UNION # union file system
58 #file-system MFS # memory-based filesystem
59
60 #options NFSSERVER # nfs server support
61 #options QUOTA # FFS quotas
62 #options FFS_EI # FFS Endian Independant support
63 #options SOFTDEP # FFS soft updates support.
64 #options NFS_V2_ONLY # Exclude NFS3 and NQNFS code to save space
65 options VNODE_OP_NOINLINE # Save space by not inlining vnode op calls
66
67 # Networking options
68 options INET # IP prototol stack support
69 #options INET6 # IPV6
70 #options IPSEC # IP security
71 #options IPSEC_ESP # IP security (encryption part; define w/IPSEC)
72 #options IPSEC_DEBUG # debug for IP security
73 #options GATEWAY # IP packet forwarding
74 #options ISO,TPIP # OSI networking
75 #options EON # OSI tunneling over IP
76 #options CCITT,LLC,HDLC # X.25
77 #options PFIL_HOOKS # pfil(9) packet filter hooks.
78 #options TCP_DEBUG # Record last TCP_NDEBUG packets with SO_DEBUG
79
80 # Work-around for root on slow servers (insurance...)
81 options NFS_BOOT_RWSIZE=1024
82 options NFS_BOOT_BOOTPARAM
83
84 config netbsd root on ? type ?
85
86 #### Main bus.
87 mainbus0 at root
88
89 #### Bus types.
90
91 obio0 at mainbus? # all Sun-2
92 obmem0 at mainbus? # all Sun-2
93 mbmem0 at mainbus? # 2/120, 2/170
94 mbio0 at mainbus? # 2/120, 2/170
95 sun68kvme0 at mainbus? # 2/50, 2/130, 2/160
96 vme0 at sun68kvme0 # mi VME attachment
97
98 #### Standard system devices.
99
100 ## The AM9513 clock chip.
101 clock0 at obio0 addr 0x002800 # 2/120, 2/170
102 clock0 at obio0 addr 0x7f2800 # 2/50, 2/130, 2/160
103
104 ## The MM58167 time-of-day chip.
105 tod0 at obio0 addr 0x003800 # 2/120, 2/170
106 tod0 at vme0 addr 0x200800 # 2/50, 2/130, 2/160
107
108 #### Serial port configuration.
109
110 ## Zilog 8530 serial chips. Each has two channels.
111 ## zs0 is ttya and ttyb. zs1 is the keyboard and mouse.
112 ## zs0 is REQUIRED to use KGDB.
113 zs0 at obio0 addr 0x002000 # 2/120, 2/170
114 zs0 at obio0 addr 0x7f2000 # 2/50
115 zs1 at obmem0 addr 0x780000 # 2/120, 2/170
116 zs1 at obio0 addr 0x7f1800 # 2/50
117 #zs2 at mbmem0 addr 0x080800 # 2/120, 2/170 (first sc SCSI)
118 #zs3 at mbmem0 addr 0x081000 # 2/120, 2/170 (first sc SCSI)
119 #zs4 at mbmem0 addr 0x084800 # 2/120, 2/170 (second sc SCSI)
120 #zs5 at mbmem0 addr 0x085000 # 2/120, 2/170 (second sc SCSI)
121 zstty* at zs? channel ? # ttya
122 kbd0 at zstty? # keyboard
123 #ms0 at zstty? # mouse
124
125 #### Disk controllers and disks.
126
127 ## PAL+logic-based "Sun SCSI 2" Multibus/VME SCSI controller.
128 ## This driver has several flags which may be enabled using
129 ## the "flags" directive. Valid flags are:
130 ##
131 ## 0x0ff Set (1<<target) to disable parity checking
132 ## 0x100 Set this bit to disable DMA interrupts (poll)
133 ## 0x200 Set this bit to disable DMA entirely (use PIO)
134 ##
135 ## For example: "flags 0x10f" would disable DMA interrupts,
136 ## and disable parity for targets 0-3
137
138 sc0 at mbmem0 addr 0x80000 ipl 2 flags 0xff
139 sc0 at vme0 addr 0x200000 irq 2 vect 0x40 flags 0xff
140 sc1 at mbmem0 addr 0x84000 ipl 2 flags 0xff
141
142 ## NCR5380-based "Sun SCSI 3" VME SCSI controller.
143 ## This driver has several flags which may be enabled by OR'ing
144 ## the values and using the "flags" directive.
145 ## Valid flags are:
146 ##
147 ## 0x01 Use DMA (may be polled)
148 ## 0x02 Use DMA completion interrupts
149 ## 0x04 Allow disconnect/reselect
150 ##
151 ## E.g. the following would enable DMA, interrupts, and reselect:
152 ## si0 at vme0 addr 0x200000 ipl 3 vect 0x40 flags 0x07
153 ##
154 ## By default, DMA is enabled in the driver.
155
156 si0 at vme0 addr 0x200000 irq 2 vect 0x40
157
158 ## These entries find devices on all SCSI busses and assign
159 ## unit numbers dynamically.
160 scsibus* at sc?
161 scsibus* at si?
162 sd* at scsibus? target ? lun ? # SCSI disks
163 st* at scsibus? target ? lun ? # SCSI tapes
164 cd* at scsibus? target ? lun ? # SCSI CD-ROMs
165 #ch* at scsibus? target ? lun ? # SCSI changer devices
166 #ss* at scsibus? target ? lun ? # SCSI scanners
167 #ses* at scsibus? target ? lun ? # SCSI SES/SAF-TE
168 #uk* at scsibus? target ? lun ? # unknown SCSI
169
170 # support old SCSI devices that don't understand the INQUIRY command
171 options SCSI_OLD_NOINQUIRY
172
173 ## Xylogics 450 or 451 Multibus/VME SMD disk controllers and disks.
174 #xyc0 at mbio0 addr 0xee40 ipl 2
175 xyc0 at vme0 addr 0xee40 irq 2 vect 0x48
176 #xyc1 at mbio0 addr 0xee48 ipl 2
177 xyc1 at vme0 addr 0xee48 irq 2 vect 0x49
178 xy* at xyc? drive ?
179
180 ## Memory-disk device.
181 #pseudo-device md 2
182
183 #### Network interfaces.
184
185 ## Intel Ethernet (onboard, or Multibus/VME)
186 ie0 at obio0 addr 0x7f0800 ipl 3 # 2/50
187 ie0 at mbmem0 addr 0x88000 ipl 3
188 ie1 at mbmem0 addr 0x8c000 ipl 3
189 ## VME: the first [addr,len] pair specifies the device registers;
190 ## the second pair specifies the on-board memory buffer
191 ie1 at vme0 addr 0xe88000,0xe00000 len -1,0x40000 irq 3 vect 0x75
192
193 ## 3Com Ethernet (Multibus only)
194 ec0 at mbmem0 addr 0xe0000 ipl 3
195 ec1 at mbmem0 addr 0xe2000 ipl 3
196
197 ## Frame buffers.
198
199 ## Sun "bwtwo" black and white framebuffer.
200 bwtwo0 at obmem0 addr 0x700000 # 2/120, 2/170
201 bwtwo0 at obio0 addr 0x0 # 2/50
202
203 ## PROM console driver -- if all else fails
204 pcons0 at mainbus0 # PROM console
205
206 #### Miscellaneous.
207 pseudo-device loop 1 # network loopback
208 #pseudo-device bpfilter 8 # packet filter
209 #pseudo-device sl 2 # CSLIP
210 #pseudo-device ppp 2 # PPP
211 #pseudo-device tun 2 # network tunneling over tty
212 #pseudo-device gre 2 # generic L3 over IP tunnel
213 #pseudo-device ipfilter # ip filter
214 #pseudo-device gif 4 # IPv[46] over IPv[46] tunnel (RFC1933)
215 #pseudo-device faith 1 # IPv[46] tcp relay translation i/f
216 #pseudo-device stf 1 # 6to4 IPv6 over IPv4 encapsulation
217 # rnd is EXPERIMENTAL
218 #pseudo-device rnd # /dev/random and in-kernel generator
219
220 pseudo-device pty 4 # pseudo-terminals
221 #pseudo-device vnd 4 # paging to files
222 #pseudo-device ccd 4 # concatenated disks
223 #pseudo-device raid 4 # RAIDframe disk driver
224 #options RAID_AUTOCONFIG # auto-configuration of RAID components
225