Home | History | Annotate | Line # | Download | only in conf
RAMDISK revision 1.21.22.1
      1  1.21.22.1  minoura #	$NetBSD: RAMDISK,v 1.21.22.1 2000/06/22 17:04:44 minoura Exp $
      2        1.1      gwr 
      3        1.1      gwr # RAMDISK: Root/swap on ramdisk
      4        1.1      gwr # This kernel is used to:
      5        1.1      gwr #	format the disk (not yet implemented)
      6        1.1      gwr #	partition the disk (disklabel)
      7        1.1      gwr #	install the miniroot in the swap partition
      8        1.1      gwr 
      9        1.5      jtc include "arch/sun3/conf/std.sun3"
     10        1.1      gwr 
     11       1.17      gwr # Machines to be supported by this kernel
     12       1.13      gwr # options 	FPU_EMULATE		# No FP code here!
     13        1.1      gwr options 	HAVECACHE		# Sun3/260 VAC
     14        1.1      gwr 
     15        1.1      gwr # Needs to be set per system.  i.e change these as you see fit
     16        1.1      gwr maxusers	2
     17        1.1      gwr 
     18        1.1      gwr # Standard system options
     19       1.13      gwr # ... debugging options
     20       1.18      gwr #options 	DDB
     21       1.19      gwr # Compatability options (none)
     22        1.6  thorpej 
     23       1.13      gwr # Filesystem options
     24       1.13      gwr # Need FFS for the ramdisk image.
     25       1.13      gwr file-system	FFS		# Berkeley Fast Filesystem
     26       1.13      gwr # May need these to get miniroot image.
     27       1.13      gwr file-system	NFS		# Sun NFS client support
     28       1.13      gwr file-system	CD9660		# ISO 9660 + Rock Ridge file system
     29        1.2      gwr 
     30       1.18      gwr # Networking options
     31       1.18      gwr options 	INET		# IP prototol stack support
     32       1.18      gwr options 	TCP_COMPAT_42	# compatibility with 4.2BSD TCP/IP
     33       1.18      gwr 
     34       1.13      gwr # Enable the hooks used for initializing the root memory-disk.
     35        1.8       pk options 	MEMORY_DISK_HOOKS
     36       1.13      gwr options 	MEMORY_DISK_IS_ROOT	# force root on memory disk
     37       1.13      gwr options 	MEMORY_DISK_SERVER=0	# no userspace memory disk support
     38  1.21.22.1  minoura options 	MINIROOTSIZE=800	# size of memory disk, in blocks
     39        1.1      gwr 
     40  1.21.22.1  minoura config		netbsd root on ? type ffs
     41        1.1      gwr 
     42       1.16      gwr # On-board I/O space (required)
     43       1.16      gwr include "arch/sun3/conf/obio.sun3"
     44       1.16      gwr 
     45       1.16      gwr # On-board memory (optional)
     46       1.16      gwr # See frame-buffers
     47       1.16      gwr # obmem0 at mainbus?
     48       1.16      gwr 
     49       1.16      gwr # VME bus support (optional)
     50       1.16      gwr # One unit for each address space
     51       1.16      gwr vme0 at mainbus? # A16/D16
     52       1.16      gwr vme1 at mainbus? # A16/D32
     53       1.16      gwr vme2 at mainbus? # A24/D16
     54       1.16      gwr vme3 at mainbus? # A24/D32
     55       1.16      gwr vme4 at mainbus? # A32/D16
     56       1.16      gwr vme5 at mainbus? # A32/D32
     57       1.16      gwr 
     58        1.2      gwr #
     59        1.3      gwr # Serial ports
     60        1.3      gwr #
     61       1.11    lukem zstty0	at zsc1 channel 0	# ttya
     62       1.11    lukem zstty1	at zsc1 channel 1	# ttyb
     63        1.3      gwr 
     64       1.11    lukem kbd0	at zsc0 channel 0	# keyboard
     65       1.13      gwr #ms0	at zsc0 channel 1	# mouse
     66        1.3      gwr 
     67        1.3      gwr #
     68        1.2      gwr # Network devices
     69        1.2      gwr #
     70        1.1      gwr 
     71        1.2      gwr # Intel Ethernet (onboard, or VME)
     72       1.16      gwr ie0 at obio0 addr 0x0C0000 ipl 3
     73       1.16      gwr ie1 at vme2  addr 0xe88000 ipl 3 vect 0x75
     74        1.1      gwr 
     75        1.2      gwr # Lance Ethernet (only onboard)
     76       1.16      gwr le0 at obio0 addr 0x120000 ipl 3
     77       1.16      gwr 
     78       1.16      gwr # All Sun3 machines with an "le" (3/50, 3/60) should be
     79       1.16      gwr # presumed to have the old, buggy LANCE chip. (Rev. C)
     80       1.16      gwr options 	LANCE_REVC_BUG
     81        1.1      gwr 
     82        1.2      gwr #
     83        1.2      gwr # Disk and tape devices
     84        1.2      gwr #
     85        1.2      gwr 
     86        1.2      gwr # Sun3 "si" SCSI controller (NCR 5380)
     87       1.13      gwr # See GENERIC for the flags description.
     88       1.16      gwr si0 at obio0 addr 0x140000 ipl 2
     89       1.16      gwr si0 at vme2  addr 0x200000 ipl 2 vect 0x40
     90       1.16      gwr si1 at vme2  addr 0x204000 ipl 2 vect 0x41
     91       1.16      gwr 
     92       1.16      gwr # Xylogics 450/451 controllers (VME A16/D16)
     93       1.16      gwr xyc0 at vme0 addr 0xee40 ipl 2 vect 0x48
     94       1.16      gwr xyc1 at vme0 addr 0xee48 ipl 2 vect 0x49
     95       1.13      gwr xy* at xyc? drive ?
     96       1.10      gwr 
     97       1.16      gwr # Xylogics 7053 controllers (VME A16/D32)
     98       1.16      gwr xdc0 at vme1 addr 0xee80 ipl 2 vect 0x44
     99       1.16      gwr xdc1 at vme1 addr 0xee90 ipl 2 vect 0x45
    100       1.13      gwr xd* at xdc? drive ?
    101        1.2      gwr 
    102        1.2      gwr # Xylogics 472 tape controllers?
    103       1.13      gwr 
    104       1.16      gwr # Sun3/E SCSI+Ethernet board (VME A24/D16)
    105       1.16      gwr # Note: the board uses vect and vect+1
    106       1.16      gwr sebuf0 at vme2 addr 0x300000 ipl 2 vect 0x74 # and 0x75
    107       1.16      gwr sebuf1 at vme2 addr 0x340000 ipl 2 vect 0x76 # and 0x77
    108       1.13      gwr si* at sebuf?
    109       1.13      gwr ie* at sebuf?
    110        1.2      gwr 
    111        1.2      gwr #
    112        1.2      gwr # Frame buffer devices
    113       1.18      gwr # (Not needed for installation kernels.)
    114        1.1      gwr 
    115        1.2      gwr #
    116        1.2      gwr # SCSI infrastructure
    117        1.2      gwr #
    118        1.1      gwr scsibus* at scsi?
    119        1.1      gwr 
    120       1.10      gwr sd* at scsibus? target ? lun ?		# SCSI disks
    121       1.10      gwr st* at scsibus? target ? lun ?		# SCSI tapes
    122       1.10      gwr cd* at scsibus? target ? lun ?		# SCSI CD-ROMs
    123       1.10      gwr #ch* at scsibus? target ? lun ?		# SCSI changer devices
    124       1.10      gwr #ss* at scsibus? target ? lun ?		# SCSI scanners
    125       1.20      gwr #uk* at scsibus? target ? lun ?		# unknown SCSI devices
    126        1.1      gwr 
    127       1.16      gwr # Memory-disk drivers (root for install tape)
    128       1.11    lukem pseudo-device	md		2
    129        1.2      gwr 
    130        1.2      gwr # Misc.
    131       1.11    lukem pseudo-device	loop		1	# network loopback
    132       1.11    lukem pseudo-device	sl		2	# CSLIP
    133