RAMDISK revision 1.9 1 # $NetBSD: RAMDISK,v 1.9 1997/01/31 02:08:24 thorpej Exp $
2
3 #
4 # RAMDISK: Root/swap on ramdisk
5 # This kernel is used to:
6 # format the disk (not yet implemented)
7 # partition the disk (disklabel)
8 # install the miniroot in the swap partition
9 #
10
11 include "arch/sun3/conf/std.sun3"
12
13 # Machines to be supported by this kernel
14 options FPU_EMULATE # XXX - Should not be needed!
15 options HAVECACHE # Sun3/260 VAC
16
17 # Needs to be set per system. i.e change these as you see fit
18 maxusers 2
19
20 # Standard system options
21
22 # Debugging options. Uncomment either this:
23 #options DDB
24 # ... or these two: (for KGDB on another machine)
25 makeoptions DEBUG="-g" # symbols for kgdb + nm
26 options KGDB
27
28 # Enable the hooks used for initializing the ram-disk.
29 options MEMORY_DISK_HOOKS
30 options MINIROOTSIZE=512 # 256K
31
32 # Filesystem options
33 # May need NFS to get miniroot image
34 file-system NFS # nfs client support
35 # Need FFS for the ramdisk image
36 file-system FFS # ufs file system
37
38 options FIFO # FIFOs; RECOMMENDED
39
40 # Networking options
41 options INET # IP prototol stack support
42 options TCP_COMPAT_42 # TCP bug compatibility with 4.2BSD
43 # XXX - Work-around for root on slow SunOS/Sun3 servers (sigh...)
44 options NFS_BOOT_RWSIZE=1024
45
46 # Compatability options
47 #options COMPAT_SUNOS # can run SunOS 4.1.1 executables
48 #options COMPAT_43 # and 4.3BSD and ...
49 #options COMPAT_10 # NetBSD 1.0
50 options COMPAT_11 # NetBSD 1.1
51 options COMPAT_12 # NetBSD 1.2
52 options UCONSOLE # Allow non-root TIOCCONS
53
54 # Sun3-specific debugging options
55 options DIAGNOSTIC
56
57 config netbsd root on ? type ?
58
59 #
60 # Serial ports
61 #
62 zstty0 at zsc1 channel 0 # ttya
63 zstty1 at zsc1 channel 1 # ttyb
64
65 kbd0 at zsc0 channel 0 # keyboard
66 ms0 at zsc0 channel 1 # mouse
67
68 #
69 # Network devices
70 #
71
72 # Intel Ethernet (onboard, or VME)
73 ie0 at obio0 addr ? level ?
74 ie1 at vmes0 addr 0xffe88000 level 3 vect 0x75
75
76 # Lance Ethernet (only onboard)
77 le0 at obio0 addr ? level ?
78
79 #
80 # Disk and tape devices
81 #
82
83 # Sun3 "si" SCSI controller (NCR 5380)
84 si0 at obio0 addr ? level ?
85 si0 at vmes0 addr 0xff200000 level 2 vect 0x40
86 si1 at vmes0 addr 0xff204000 level 2 vect 0x41
87
88 # Xylogics 7053 controllers
89 # xdc0 at vmel0 addr 0xffffee80 level 2 vect 0x44
90 # xdc1 at vmel0 addr 0xffffee90 level 2 vect 0x45
91 # xd* at xdc? drive ?
92
93 # Xylogics 450/451 controllers
94 # xyc0 at vmes0 addr 0xffffee40 level 2 vect 0x48
95 # xyc1 at vmes0 addr 0xffffee48 level 2 vect 0x49
96 # xy* at xyc? drive ?
97
98 # Xylogics 472 tape controllers?
99
100 #
101 # Frame buffer devices
102 # (Not needed for the RAMDISK installation kernel)
103
104 #
105 # SCSI infrastructure
106 #
107 scsibus* at scsi?
108
109 # Sun compatible scsi device mappings
110 sd0 at scsibus? target 0 lun 0
111 sd1 at scsibus? target 0 lun 1
112 sd2 at scsibus? target 1 lun 0
113 sd3 at scsibus? target 1 lun 1
114 sd* at scsibus? target ? lun ?
115
116 st0 at scsibus? target 4 lun 0
117 st1 at scsibus? target 5 lun 0
118 st* at scsibus? target ? lun ?
119
120 cd0 at scsibus? target 6 lun 0
121 cd* at scsibus? target ? lun ?
122
123 #ch* at scsibus? target ? lun ?
124
125 # Memory-disk (root for install tape)
126 pseudo-device md 2 # Memory-disk
127
128 # Misc.
129 pseudo-device loop 1 # network loopback
130 pseudo-device sl 2 # CSLIP
131 pseudo-device ppp 2 # PPP
132
133