dbcool_var.h revision 1.15 1 1.15 rin /* $NetBSD: dbcool_var.h,v 1.15 2020/04/16 21:56:42 rin Exp $ */
2 1.1 pgoyette
3 1.1 pgoyette /*-
4 1.1 pgoyette * Copyright (c) 2008 The NetBSD Foundation, Inc.
5 1.1 pgoyette * All rights reserved.
6 1.1 pgoyette *
7 1.1 pgoyette * This code is derived from software contributed to The NetBSD Foundation
8 1.1 pgoyette * by Paul Goyette
9 1.1 pgoyette *
10 1.1 pgoyette * Redistribution and use in source and binary forms, with or without
11 1.1 pgoyette * modification, are permitted provided that the following conditions
12 1.1 pgoyette * are met:
13 1.1 pgoyette * 1. Redistributions of source code must retain the above copyright
14 1.1 pgoyette * notice, this list of conditions and the following disclaimer.
15 1.1 pgoyette * 2. Redistributions in binary form must reproduce the above copyright
16 1.1 pgoyette * notice, this list of conditions and the following disclaimer in the
17 1.1 pgoyette * documentation and/or other materials provided with the distribution.
18 1.1 pgoyette *
19 1.1 pgoyette * THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS
20 1.1 pgoyette * ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
21 1.1 pgoyette * TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
22 1.1 pgoyette * PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE FOUNDATION OR CONTRIBUTORS
23 1.1 pgoyette * BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
24 1.1 pgoyette * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
25 1.1 pgoyette * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
26 1.1 pgoyette * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
27 1.1 pgoyette * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
28 1.1 pgoyette * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
29 1.1 pgoyette * POSSIBILITY OF SUCH DAMAGE.
30 1.1 pgoyette */
31 1.1 pgoyette
32 1.1 pgoyette /*
33 1.1 pgoyette * A driver for dbCool(tm) family of environmental controllers
34 1.1 pgoyette */
35 1.1 pgoyette
36 1.1 pgoyette #ifndef DBCOOLVAR_H
37 1.1 pgoyette #define DBCOOLVAR_H
38 1.1 pgoyette
39 1.13 pgoyette #ifdef DEBUG
40 1.1 pgoyette #define DBCOOL_DEBUG
41 1.13 pgoyette #endif
42 1.1 pgoyette
43 1.1 pgoyette #include <dev/i2c/i2cvar.h>
44 1.1 pgoyette
45 1.1 pgoyette #include <dev/sysmon/sysmonvar.h>
46 1.1 pgoyette
47 1.1 pgoyette #include <dev/i2c/dbcool_reg.h>
48 1.1 pgoyette
49 1.1 pgoyette enum dbc_pwm_params {
50 1.1 pgoyette DBC_PWM_BEHAVIOR = 0,
51 1.1 pgoyette DBC_PWM_MIN_DUTY,
52 1.1 pgoyette DBC_PWM_MAX_DUTY,
53 1.1 pgoyette DBC_PWM_CUR_DUTY,
54 1.1 pgoyette DBC_PWM_LAST_PARAM
55 1.1 pgoyette };
56 1.1 pgoyette
57 1.1 pgoyette enum dbc_sensor_type {
58 1.1 pgoyette DBC_CTL = 0,
59 1.1 pgoyette DBC_TEMP,
60 1.1 pgoyette DBC_VOLT,
61 1.1 pgoyette DBC_FAN,
62 1.9 pgoyette DBC_VID,
63 1.1 pgoyette DBC_EOF
64 1.1 pgoyette };
65 1.1 pgoyette
66 1.1 pgoyette #define DBCFLAG_TEMPOFFSET 0x0001
67 1.1 pgoyette #define DBCFLAG_HAS_MAXDUTY 0x0002
68 1.1 pgoyette #define DBCFLAG_HAS_SHDN 0x0004
69 1.1 pgoyette #define DBCFLAG_MULTI_VCC 0x0008
70 1.1 pgoyette #define DBCFLAG_4BIT_VER 0x0010
71 1.9 pgoyette #define DBCFLAG_OBSOLETE 0x0020 /* was DBCFLAG_HAS_VID */
72 1.1 pgoyette #define DBCFLAG_HAS_VID_SEL 0x0040
73 1.2 pgoyette #define DBCFLAG_HAS_PECI 0x0080
74 1.9 pgoyette #define DBCFLAG_NO_READBYTE 0x1000
75 1.1 pgoyette #define DBCFLAG_ADM1030 0x2000
76 1.1 pgoyette #define DBCFLAG_ADT7466 0x4000
77 1.1 pgoyette
78 1.1 pgoyette /* Maximum sensors for any dbCool device */
79 1.9 pgoyette #define DBCOOL_MAXSENSORS 16
80 1.1 pgoyette
81 1.1 pgoyette struct reg_list {
82 1.1 pgoyette uint8_t val_reg;
83 1.1 pgoyette uint8_t hi_lim_reg;
84 1.1 pgoyette uint8_t lo_lim_reg;
85 1.1 pgoyette };
86 1.1 pgoyette
87 1.1 pgoyette struct dbcool_sensor {
88 1.1 pgoyette enum dbc_sensor_type type;
89 1.1 pgoyette struct reg_list reg;
90 1.1 pgoyette int name_index;
91 1.1 pgoyette int sysctl_index;
92 1.2 pgoyette int nom_volt_index;
93 1.1 pgoyette };
94 1.1 pgoyette
95 1.1 pgoyette /*
96 1.1 pgoyette * The members of dbcool_power_control need to stay in the same order
97 1.1 pgoyette * as the enum dbc_pwm_params above
98 1.1 pgoyette */
99 1.1 pgoyette struct dbcool_power_control {
100 1.2 pgoyette uint8_t power_regs[DBC_PWM_LAST_PARAM];
101 1.1 pgoyette const char *desc;
102 1.1 pgoyette };
103 1.1 pgoyette
104 1.1 pgoyette struct chip_id;
105 1.1 pgoyette
106 1.6 christos struct dbcool_chipset {
107 1.6 christos i2c_tag_t dc_tag;
108 1.6 christos i2c_addr_t dc_addr;
109 1.6 christos void (*dc_writereg)(struct dbcool_chipset *, uint8_t, uint8_t);
110 1.6 christos uint8_t (*dc_readreg)(struct dbcool_chipset *, uint8_t);
111 1.6 christos struct chip_id *dc_chip;
112 1.6 christos };
113 1.6 christos
114 1.1 pgoyette struct dbcool_softc {
115 1.5 cegger device_t sc_dev;
116 1.1 pgoyette struct sysmon_envsys *sc_sme;
117 1.6 christos struct dbcool_chipset sc_dc;
118 1.1 pgoyette envsys_data_t sc_sensor[DBCOOL_MAXSENSORS];
119 1.12 pgoyette sysmon_envsys_lim_t sc_deflims[DBCOOL_MAXSENSORS];
120 1.12 pgoyette uint32_t sc_defprops[DBCOOL_MAXSENSORS];
121 1.11 pgoyette int sc_root_sysctl_num;
122 1.1 pgoyette int sc_sysctl_num[DBCOOL_MAXSENSORS];
123 1.1 pgoyette struct reg_list *sc_regs[DBCOOL_MAXSENSORS];
124 1.2 pgoyette int sc_nom_volt[DBCOOL_MAXSENSORS];
125 1.2 pgoyette int sc_temp_offset;
126 1.2 pgoyette int64_t sc_supply_voltage;
127 1.2 pgoyette bool sc_suspend;
128 1.14 pgoyette struct sysctllog *sc_sysctl_log;
129 1.1 pgoyette #ifdef DBCOOL_DEBUG
130 1.1 pgoyette uint8_t sc_user_reg;
131 1.1 pgoyette #endif
132 1.1 pgoyette };
133 1.1 pgoyette
134 1.1 pgoyette struct chip_id {
135 1.1 pgoyette uint8_t company;
136 1.1 pgoyette uint8_t device;
137 1.1 pgoyette uint8_t rev;
138 1.1 pgoyette struct dbcool_sensor *table;
139 1.1 pgoyette struct dbcool_power_control *power;
140 1.1 pgoyette int flags;
141 1.1 pgoyette int rpm_dividend;
142 1.1 pgoyette const char *name;
143 1.1 pgoyette };
144 1.1 pgoyette
145 1.1 pgoyette /*
146 1.1 pgoyette * Expose some routines for the macppc's ki2c match/attach routines
147 1.1 pgoyette */
148 1.6 christos uint8_t dbcool_readreg(struct dbcool_chipset *, uint8_t);
149 1.6 christos void dbcool_writereg(struct dbcool_chipset *, uint8_t, uint8_t);
150 1.1 pgoyette void dbcool_setup(device_t);
151 1.6 christos int dbcool_chip_ident(struct dbcool_chipset *);
152 1.8 dyoung bool dbcool_pmf_suspend(device_t, const pmf_qual_t *);
153 1.8 dyoung bool dbcool_pmf_resume(device_t, const pmf_qual_t *);
154 1.1 pgoyette
155 1.1 pgoyette #endif /* def DBCOOLVAR_H */
156