hytp14var.h revision 1.2.6.2 1 /* $NetBSD: hytp14var.h,v 1.2.6.2 2016/07/09 20:25:02 skrll Exp $ */
2
3 /*-
4 * Copyright (c) 2014,2016 The NetBSD Foundation, Inc.
5 * All rights reserved.
6 *
7 * This code is derived from software contributed to The NetBSD Foundation
8 * by Frank Kardel.
9 *
10 * Redistribution and use in source and binary forms, with or without
11 * modification, are permitted provided that the following conditions
12 * are met:
13 * 1. Redistributions of source code must retain the above copyright
14 * notice, this list of conditions and the following disclaimer.
15 * 2. Redistributions in binary form must reproduce the above copyright
16 * notice, this list of conditions and the following disclaimer in the
17 * documentation and/or other materials provided with the distribution.
18 *
19 * THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS
20 * ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
21 * TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
22 * PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE FOUNDATION OR CONTRIBUTORS
23 * BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
24 * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
25 * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
26 * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
27 * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
28 * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
29 * POSSIBILITY OF SUCH DAMAGE.
30 */
31
32 /*
33 * IST-AG P14 calibrated Hygro-/Temperature sensor module
34 * Devices: HYT-271, HYT-221 and HYT-939
35 *
36 * see:
37 * http://www.ist-ag.com/eh/ist-ag/resource.nsf/imgref/Download_AHHYTM_E2.1.pdf/
38 * $FILE/AHHYTM_E2.1.pdf
39 */
40 #ifndef _DEV_I2C_HYTP14VAR_H_
41 #define _DEV_I2C_HYTP14VAR_H_
42
43 #define HYTP14_DEFAULT_ADDR 0x28
44
45 #define HYTP14_NUM_SENSORS 2
46
47 /* the default measurement interval is 50 seconds */
48 #define HYTP14_MR_INTERVAL 50
49
50 #define HYTP14_THR_INIT 0
51 #define HYTP14_THR_RUN 1
52 #define HYTP14_THR_STOP 2
53
54 struct hytp14_sc {
55 device_t sc_dev;
56 i2c_tag_t sc_tag;
57 i2c_addr_t sc_addr;
58
59 kmutex_t sc_mutex;
60 kcondvar_t sc_condvar;
61 struct lwp *sc_thread; /* measurement poll thread */
62 int sc_state; /* thread communication */
63
64 int sc_valid; /* ENVSYS validity state for this sensor */
65 uint8_t sc_data[4]; /* current sensor data */
66 uint8_t sc_last[4]; /* last sensor data, before MR */
67
68 int sc_numsensors;
69
70 int32_t sc_mrinterval;
71
72 struct sysmon_envsys *sc_sme;
73 envsys_data_t sc_sensors[HYTP14_NUM_SENSORS];
74 };
75
76 struct hytp14_sensor {
77 const char *desc;
78 enum envsys_units type;
79 void (*refresh)(struct hytp14_sc *, envsys_data_t *);
80 };
81
82 #endif
83