sysmon_envsys_tables.c revision 1.12.26.1 1 /* $NetBSD: sysmon_envsys_tables.c,v 1.12.26.1 2018/06/25 07:26:02 pgoyette Exp $ */
2
3 /*-
4 * Copyright (c) 2007 Juan Romero Pardines.
5 * All rights reserved.
6 *
7 * Redistribution and use in source and binary forms, with or without
8 * modification, are permitted provided that the following conditions
9 * are met:
10 * 1. Redistributions of source code must retain the above copyright
11 * notice, this list of conditions and the following disclaimer.
12 * 2. Redistributions in binary form must reproduce the above copyright
13 * notice, this list of conditions and the following disclaimer in the
14 * documentation and/or other materials provided with the distribution.
15 *
16 * THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
17 * IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
18 * OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
19 * IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
20 * INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
21 * NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
22 * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
23 * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
24 * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
25 * THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
26 */
27
28 #include <sys/cdefs.h>
29 __KERNEL_RCSID(0, "$NetBSD: sysmon_envsys_tables.c,v 1.12.26.1 2018/06/25 07:26:02 pgoyette Exp $");
30
31 #include <sys/types.h>
32
33 #include <dev/sysmon/sysmonvar.h>
34 #include <dev/sysmon/sysmon_envsysvar.h>
35
36 /*
37 * Available units type descriptions.
38 */
39 static const struct sme_descr_entry sme_units_description[] = {
40 { ENVSYS_STEMP, PENVSYS_TYPE_TEMP, "Temperature" },
41 { ENVSYS_SFANRPM, PENVSYS_TYPE_FAN, "Fan" },
42 { ENVSYS_SVOLTS_AC, PENVSYS_TYPE_VOLTAGE, "Voltage AC" },
43 { ENVSYS_SVOLTS_DC, PENVSYS_TYPE_VOLTAGE, "Voltage DC" },
44 { ENVSYS_SOHMS, PENVSYS_TYPE_RESISTANCE,"Ohms" },
45 { ENVSYS_SWATTS, PENVSYS_TYPE_POWER, "Watts" },
46 { ENVSYS_SAMPS, PENVSYS_TYPE_POWER, "Ampere" },
47 { ENVSYS_SWATTHOUR, PENVSYS_TYPE_BATTERY, "Watt hour" },
48 { ENVSYS_SAMPHOUR, PENVSYS_TYPE_BATTERY, "Ampere hour" },
49 { ENVSYS_INDICATOR, PENVSYS_TYPE_INDICATOR, "Indicator" },
50 { ENVSYS_INTEGER, PENVSYS_TYPE_INDICATOR, "Integer" },
51 { ENVSYS_DRIVE, PENVSYS_TYPE_DRIVE, "Drive" },
52 { ENVSYS_BATTERY_CAPACITY, PENVSYS_TYPE_BATTERY,"Battery capacity" },
53 { ENVSYS_BATTERY_CHARGE, -1, "Battery charge" },
54 { ENVSYS_SRELHUMIDITY, -1, "relative Humidity" },
55 { ENVSYS_LUX, -1, "Illuminance" },
56 { -1, -1, "unknown" }
57 };
58
59 /*
60 * Available sensor state descriptions.
61 */
62 static const struct sme_descr_entry sme_state_description[] = {
63 { ENVSYS_SVALID, -1, "valid" },
64 { ENVSYS_SINVALID, -1, "invalid" },
65 { ENVSYS_SCRITICAL, -1, "critical" },
66 { ENVSYS_SCRITUNDER, -1, "critical-under" },
67 { ENVSYS_SCRITOVER, -1, "critical-over" },
68 { ENVSYS_SWARNUNDER, -1, "warning-under" },
69 { ENVSYS_SWARNOVER, -1, "warning-over" },
70 { -1, -1, "unknown" }
71 };
72
73 /*
74 * Available drive state descriptions.
75 */
76 static const struct sme_descr_entry sme_drivestate_description[] = {
77 { ENVSYS_DRIVE_EMPTY, -1, "unknown" },
78 { ENVSYS_DRIVE_READY, -1, "ready" },
79 { ENVSYS_DRIVE_POWERUP, -1, "powering up" },
80 { ENVSYS_DRIVE_ONLINE, -1, "online" },
81 { ENVSYS_DRIVE_OFFLINE, -1, "offline" },
82 { ENVSYS_DRIVE_IDLE, -1, "idle" },
83 { ENVSYS_DRIVE_ACTIVE, -1, "active" },
84 { ENVSYS_DRIVE_BUILD, -1, "building" },
85 { ENVSYS_DRIVE_REBUILD, -1, "rebuilding" },
86 { ENVSYS_DRIVE_POWERDOWN, -1, "powering down" },
87 { ENVSYS_DRIVE_FAIL, -1, "failed" },
88 { ENVSYS_DRIVE_PFAIL, -1, "degraded" },
89 { ENVSYS_DRIVE_MIGRATING, -1, "migrating" },
90 { ENVSYS_DRIVE_CHECK, -1, "checking" },
91 { -1, -1, "unknown" }
92 };
93
94 /*
95 * Available battery capacity descriptions.
96 */
97 static const struct sme_descr_entry sme_batterycap_description[] = {
98 { ENVSYS_BATTERY_CAPACITY_NORMAL, -1, "NORMAL" },
99 { ENVSYS_BATTERY_CAPACITY_WARNING, -1, "WARNING" },
100 { ENVSYS_BATTERY_CAPACITY_CRITICAL, -1, "CRITICAL" },
101 { ENVSYS_BATTERY_CAPACITY_LOW, -1, "LOW" },
102 { -1, -1, "UNKNOWN" }
103 };
104
105 /*
106 * Available indicator descriptions.
107 */
108 static const struct sme_descr_entry sme_indicator_description[] = {
109 { ENVSYS_INDICATOR_FALSE, -1, "FALSE" },
110 { ENVSYS_INDICATOR_TRUE, -1, "TRUE" },
111 { -1, -1, "UNKNOWN" }
112 };
113
114 static const struct sme_descr_entry *
115 sme_find_table(enum sme_descr_type table_id)
116 {
117 switch (table_id) {
118 case SME_DESC_UNITS:
119 return sme_units_description;
120 break;
121 case SME_DESC_STATES:
122 return sme_state_description;
123 break;
124 case SME_DESC_DRIVE_STATES:
125 return sme_drivestate_description;
126 break;
127 case SME_DESC_BATTERY_CAPACITY:
128 return sme_batterycap_description;
129 break;
130 case SME_DESC_INDICATOR:
131 return sme_indicator_description;
132 break;
133 default:
134 return NULL;
135 }
136 }
137
138 /*
139 * Returns the entry from specified table with type == key
140 */
141 const struct sme_descr_entry *
142 sme_find_table_entry(enum sme_descr_type table_id, int key)
143 {
144 const struct sme_descr_entry *table = sme_find_table(table_id);
145
146 if (table != NULL)
147 for (; table->type != -1; table++)
148 if (table->type == key)
149 return table;
150
151 return NULL;
152 }
153
154 const struct sme_descr_entry *
155 sme_find_table_desc(enum sme_descr_type table_id, const char *str)
156 {
157 const struct sme_descr_entry *table = sme_find_table(table_id);
158
159 if (table != NULL)
160 for (; table->type != -1; table++)
161 if (strcmp(table->desc, str) == 0)
162 return table;
163 return NULL;
164 }
165