INSTALL revision 1.23 1 1.23 pk # $NetBSD: INSTALL,v 1.23 2000/10/20 11:24:48 pk Exp $
2 1.1 mrg #
3 1.8 mrg # from: NetBSD: GENERIC,v 1.84 1999/06/06 13:00:03 mrg Exp
4 1.1 mrg #
5 1.1 mrg # floppy install kernel. try to keep this in sync with GENERIC but
6 1.1 mrg # leave as much disabled as possible.
7 1.1 mrg
8 1.1 mrg include "arch/sparc/conf/std.sparc"
9 1.20 abs
10 1.20 abs makeoptions COPTS="-Os" # Optimise for space. Implies -O2
11 1.1 mrg
12 1.1 mrg maxusers 32
13 1.1 mrg
14 1.1 mrg # Enable the hooks used for initializing the root memory-disk.
15 1.1 mrg options MEMORY_DISK_HOOKS
16 1.1 mrg options MEMORY_DISK_IS_ROOT # force root on memory disk
17 1.1 mrg options MEMORY_DISK_SERVER=0 # no userspace memory disk support
18 1.23 pk ## The miniroot size must be kept in sync manually with the size of
19 1.23 pk ## the `ramdisk' image (which is built in distrib/sparc/ramdisk).
20 1.23 pk options MINIROOTSIZE=1360 # size of memory disk, in blocks
21 1.1 mrg
22 1.1 mrg pseudo-device md 1 # memory disk device (ramdisk)
23 1.1 mrg
24 1.1 mrg ## System kernel configuration. See options(4) for more detail.
25 1.1 mrg
26 1.9 mrg
27 1.1 mrg # Options for variants of the Sun SPARC architecure.
28 1.1 mrg # We currently support three architecture types; at least one is required.
29 1.1 mrg #options SUN4 # sun4/100, sun4/200, sun4/300
30 1.1 mrg options SUN4C # sun4c - SS1, 1+, 2, ELC, SLC, IPC, IPX, etc.
31 1.1 mrg options SUN4M # sun4m - SS10, SS20, Classic, etc.
32 1.1 mrg
33 1.1 mrg #options SUN4_MMU3L # 3-level MMU on sun4/400; (incomplete)
34 1.1 mrg
35 1.1 mrg ## System options specific to the sparc machine type
36 1.1 mrg
37 1.1 mrg # Blink the power LED on some machines to indicate the system load.
38 1.1 mrg #options BLINK
39 1.1 mrg
40 1.1 mrg ## Use a faster console than the PROM's slow drawing routines. Not needed
41 1.1 mrg ## for headless (no framebuffer) machines.
42 1.5 ad #options RASTERCONSOLE # fast rasterop console
43 1.6 ad #options FONT_GALLANT12x22 # the console font
44 1.6 ad #options FONT_BOLD8x16 # a somewhat smaller font
45 1.21 abs #options RASTERCONSOLE_FGCOL=WSCOL_BLACK
46 1.21 abs #options RASTERCONSOLE_BGCOL=WSCOL_WHITE
47 1.1 mrg
48 1.1 mrg #### System options that are the same for all ports
49 1.1 mrg
50 1.1 mrg ## Root device configuration: change the ?'s if you are going to use a
51 1.1 mrg ## nonstandard root partition (other than where the kernel is booted from)
52 1.1 mrg ## and/or nonstandard root type (not ffs or nfs). Normally this can be
53 1.1 mrg ## automagically determined at boot time.
54 1.1 mrg
55 1.1 mrg config netbsd root on ? type ?
56 1.1 mrg
57 1.1 mrg ## System call tracing (see ktrace(1)).
58 1.1 mrg #options KTRACE
59 1.1 mrg
60 1.1 mrg ## Collect statistics on kernel malloc's and free's. This does have a
61 1.1 mrg ## significant performance hit on slower machines, so it is intended for
62 1.1 mrg ## diagnostic use only.
63 1.17 abs #options KMEMSTATS
64 1.1 mrg
65 1.1 mrg ## System V compatible IPC subsystem. (msgctl(2), semctl(2), and shmctl(2))
66 1.1 mrg #options SYSVMSG # System V message queues
67 1.1 mrg #options SYSVSEM # System V semaphores
68 1.1 mrg #options SYSVSHM # System V shared memory
69 1.1 mrg #options SHMMAXPGS=1024 # 1024 pages is the default
70 1.1 mrg
71 1.1 mrg ## Loadable kernel module support; still under development.
72 1.1 mrg #options LKM
73 1.1 mrg
74 1.1 mrg ## NFS boot options; default on sparc is the bootparam protocol
75 1.1 mrg options NFS_BOOT_BOOTPARAM
76 1.1 mrg #options NFS_BOOT_BOOTP
77 1.1 mrg #options NFS_BOOT_DHCP
78 1.1 mrg
79 1.1 mrg #### Debugging options
80 1.1 mrg
81 1.1 mrg ## The DDB in-kernel debugger runs at panic (unless DDB_ONPANIC=0), or at
82 1.1 mrg ## serial console break or keyboard reset, where the PROM would normally
83 1.1 mrg ## intercept. DDB_HISTORY_SIZE adds up/down arrow command history.
84 1.17 abs #options DDB # kernel dynamic debugger
85 1.1 mrg #options DDB_HISTORY_SIZE=100 # enable history editing in DDB
86 1.8 mrg #options DDB_ONPANIC=1 # see also sysctl(8): `ddb.onpanic'
87 1.1 mrg
88 1.1 mrg ## You may also use gdb, on another computer connected to this machine over
89 1.1 mrg ## a serial port. Both KGDBDEV and KGDBRATE should be specified; KGDBDEV is
90 1.1 mrg ## a dev_t encoded device number of the serial port to use.
91 1.1 mrg ## (0xc01 = ttya, 0xc02 = ttyb.)
92 1.1 mrg #options KGDB # support for kernel gdb
93 1.1 mrg #options KGDBDEV=0xc01 # kgdb device number (this sample is `ttyb')
94 1.1 mrg #options KGDBRATE=38400 # baud rate
95 1.1 mrg
96 1.1 mrg
97 1.1 mrg ## Compile the kernel with debugging symbols (`netbsd.gdb' is the debug file),
98 1.1 mrg ## such that gdb(1) can be used on a kernel coredump.
99 1.1 mrg
100 1.1 mrg #makeoptions DEBUG="-g"
101 1.1 mrg
102 1.1 mrg
103 1.1 mrg ## Adds code to the kernel that does internal consistency checks, and will
104 1.1 mrg ## cause the kernel to panic if corruption of internal data structures
105 1.1 mrg ## is detected.
106 1.1 mrg #options DIAGNOSTIC # extra kernel sanity checking
107 1.1 mrg
108 1.1 mrg ## Enable (possibly expensive) debugging code that may also display messages
109 1.1 mrg ## on the system console
110 1.1 mrg #options DEBUG
111 1.13 augustss
112 1.13 augustss #options MIIVERBOSE # verbose PHY autoconfig messages
113 1.1 mrg
114 1.1 mrg ## Make SCSI error messages more verbose when explaining their meanings.
115 1.1 mrg #options SCSIVERBOSE
116 1.1 mrg
117 1.1 mrg ## `INSECURE' turns off the kernel security level (securelevel = 0 always).
118 1.1 mrg ## This allows writing to /dev/mem, loading kernel modules while multi-user,
119 1.1 mrg ## and other insecurities good only for development work. Do not use this
120 1.1 mrg ## option on a production machine.
121 1.1 mrg options INSECURE
122 1.1 mrg
123 1.1 mrg ## Allow non-root users to grab /dev/console with programs such as xconsole.
124 1.1 mrg ## `xconsole' therefore does not need setuid root with this option enabled.
125 1.1 mrg #options UCONSOLE
126 1.1 mrg
127 1.1 mrg ## `FDSCRIPTS' allows non-readable but executable scripts by providing a
128 1.1 mrg ## pre-opened opaque file to the script interpreter. `SETUIDSCRIPTS',
129 1.1 mrg ## which implies FDSCRIPTS, allows scripts to be set-user-id using the same
130 1.1 mrg ## opaque file mechanism. Perl calls this "secure setuid scripts."
131 1.1 mrg
132 1.1 mrg #options FDSCRIPTS
133 1.1 mrg #options SETUIDSCRIPTS
134 1.1 mrg
135 1.1 mrg ## Options for compatibility with previous releases foreign system binaries.
136 1.1 mrg ## In the cases of COMPAT_SUNOS and COMPAT_SVR4, you may need to set up
137 1.1 mrg ## additional user-level utilities or system configuration files. See
138 1.1 mrg ## compat_sunos(8) and compat_svr4(8).
139 1.1 mrg
140 1.1 mrg #options COMPAT_43 # 4.3BSD system interfaces
141 1.1 mrg #options COMPAT_10 # NetBSD 1.0 binary compatibility
142 1.1 mrg #options COMPAT_11 # NetBSD 1.1 binary compatibility
143 1.1 mrg #options COMPAT_12 # NetBSD 1.2 binary compatibility
144 1.17 abs #options COMPAT_13 # NetBSD 1.3 binary compatibility
145 1.17 abs #options COMPAT_14 # NetBSD 1.4 binary compatibility
146 1.1 mrg #options COMPAT_SUNOS # SunOS 4.x binary compatibility
147 1.1 mrg #options COMPAT_SVR4 # SunOS 5.x binary compatibility
148 1.1 mrg
149 1.1 mrg ## File systems. You probably need at least one of FFS or NFS.
150 1.1 mrg file-system FFS # Berkeley Fast Filesystem
151 1.1 mrg file-system NFS # Sun NFS-compatible filesystem client
152 1.15 pk #file-system KERNFS # kernel data-structure filesystem
153 1.1 mrg #file-system NULLFS # NULL layered filesystem
154 1.23 pk file-system MFS # memory-based filesystem
155 1.1 mrg #file-system FDESC # user file descriptor filesystem
156 1.1 mrg #file-system UMAPFS # uid/gid remapping filesystem
157 1.1 mrg #file-system LFS # Log-based filesystem (still experimental)
158 1.1 mrg #file-system PORTAL # portal filesystem (still experimental)
159 1.1 mrg #file-system PROCFS # /proc
160 1.1 mrg file-system CD9660 # ISO 9660 + Rock Ridge file system
161 1.1 mrg #file-system UNION # union file system
162 1.1 mrg #file-system MSDOSFS # MS-DOS FAT filesystem(s).
163 1.1 mrg
164 1.21 abs ## File system options
165 1.1 mrg #options NFSSERVER # Sun NFS-compatible filesystem server
166 1.1 mrg #options QUOTA # FFS quotas
167 1.1 mrg #options FFS_EI # FFS Endian Independent support
168 1.21 abs #options NFS_V2_ONLY # Exclude NFS3 and NQNFS code to save space
169 1.21 abs #options VNODE_OP_NOINLINE # Save space by not inlining vnode op calls
170 1.1 mrg
171 1.1 mrg ## Network protocol support. In most environments, INET is required.
172 1.1 mrg options INET # IP (Internet Protocol) v4
173 1.17 abs #options TCP_COMPAT_42 # 4.2BSD IP implementation compatibility
174 1.1 mrg #options GATEWAY # packet forwarding ("router switch")
175 1.1 mrg #options MROUTING # packet forwarding of multicast packets
176 1.1 mrg #options DIRECTED_BROADCAST # allow broadcasts through routers
177 1.1 mrg #options NS # Xerox NS networking
178 1.1 mrg #options NSIP # Xerox NS tunneling over IP
179 1.1 mrg #options ISO,TPIP # OSI networking
180 1.1 mrg #options EON # OSI tunneling over IP
181 1.1 mrg #options CCITT,LLC,HDLC # X.25 packet switched protocol
182 1.1 mrg #options NETATALK # AppleTalk (over Ethernet) protocol
183 1.1 mrg #options NTP # Network Time Protocol in-kernel support
184 1.1 mrg #options PPS_SYNC # Add serial line synchronization for NTP
185 1.1 mrg #options PFIL_HOOKS # Add pfil(9) hooks, intended for custom LKMs.
186 1.1 mrg #options IPFILTER_LOG # Add ipmon(8) logging for ipfilter device
187 1.1 mrg #options PPP_BSDCOMP # Add BSD compression to ppp device
188 1.1 mrg #options PPP_DEFLATE # Add deflate (libz) compression to ppp device
189 1.1 mrg #options PPP_FILTER # Add active filters for ppp (via bpf)
190 1.1 mrg
191 1.1 mrg
192 1.1 mrg
193 1.1 mrg #### Main bus and CPU .. all systems.
194 1.1 mrg mainbus0 at root
195 1.1 mrg cpu0 at mainbus0
196 1.1 mrg
197 1.1 mrg #### Bus types found on SPARC systems.
198 1.1 mrg
199 1.1 mrg sbus0 at mainbus0 # sun4c
200 1.1 mrg obio0 at mainbus0 # sun4 and sun4m
201 1.10 drochner #sparcvme0 at mainbus0 # sun4
202 1.1 mrg iommu0 at mainbus0 # sun4m
203 1.1 mrg sbus0 at iommu0 # sun4m
204 1.10 drochner sparcvme0 at iommu0 # sun4m
205 1.10 drochner #vme0 at sparcvme0 # mi VME attachment
206 1.1 mrg
207 1.1 mrg ## SBus expander box
208 1.9 mrg xbox* at sbus? slot ? offset ?
209 1.9 mrg sbus* at xbox?
210 1.1 mrg
211 1.8 mrg ## SBus to PCMCIA bridge
212 1.8 mrg # Currently enabling nell* with audioamd* causes panic at attach
213 1.8 mrg #nell* at sbus? slot ? offset ? # PCMCIA bridge
214 1.8 mrg #pcmcia* at nell?
215 1.8 mrg
216 1.1 mrg #### Standard system devices -- all required for a given architecture
217 1.1 mrg
218 1.1 mrg ## Auxiliary system registers on sun4c and sun4m
219 1.1 mrg auxreg0 at mainbus0 # sun4c
220 1.1 mrg auxreg0 at obio0 # sun4m
221 1.1 mrg
222 1.1 mrg ## Power status and control register on Sun4m systems
223 1.1 mrg power0 at obio0
224 1.1 mrg
225 1.1 mrg ## Mostek clock found on 4/300, sun4c, and sun4m systems.
226 1.1 mrg ## The Mostek clock NVRAM is the "eeprom" on sun4/300 systems.
227 1.1 mrg clock0 at mainbus0 # sun4c
228 1.1 mrg clock0 at obio0 # sun4m
229 1.1 mrg #clock0 at obio0 addr 0xf2000000 # sun4/300
230 1.1 mrg
231 1.1 mrg ## Intersil clock found on 4/100 and 4/200 systems.
232 1.1 mrg #oclock0 at obio0 addr 0xf3000000 # sun4/200
233 1.1 mrg #oclock0 at obio0 addr 0x03000000 # sun4/100
234 1.1 mrg
235 1.1 mrg ## Memory error registers.
236 1.1 mrg memreg0 at mainbus0 # sun4c
237 1.1 mrg memreg0 at obio0 # sun4m
238 1.1 mrg #memreg0 at obio0 addr 0xf4000000 # sun4/200 and sun4/300
239 1.1 mrg #memreg0 at obio0 addr 0x04000000 # sun4/100
240 1.1 mrg
241 1.8 mrg ## ECC memory control
242 1.8 mrg eccmemctl0 at mainbus0 # sun4m
243 1.8 mrg
244 1.1 mrg ## Timer chip found on 4/300, sun4c, and sun4m systems.
245 1.1 mrg timer0 at mainbus0 # sun4c
246 1.1 mrg timer0 at obio0 # sun4m
247 1.1 mrg #timer0 at obio0 addr 0xef000000 # sun4/300
248 1.1 mrg
249 1.1 mrg ## EEPROM found on 4/100 and 4/200 systems. Note that the 4/300
250 1.1 mrg ## doesn't use this driver; the `EEPROM' is in the NVRAM on the
251 1.1 mrg ## Mostek clock chip on 4/300 systems.
252 1.1 mrg #eeprom0 at obio0 addr 0xf2000000 # sun4/200
253 1.1 mrg #eeprom0 at obio0 addr 0x02000000 # sun4/100
254 1.1 mrg
255 1.1 mrg
256 1.1 mrg #### Serial port configuration
257 1.1 mrg
258 1.1 mrg ## Zilog 8530 serial chips. Each has two-channels.
259 1.1 mrg ## zs0 is ttya and ttyb. zs1 is the keyboard and mouse.
260 1.1 mrg zs0 at mainbus0 # sun4c
261 1.1 mrg zs0 at obio0 # sun4m
262 1.1 mrg #zs0 at obio0 addr 0xf1000000 level 12 flags 0x103 # sun4/200 and sun4/300
263 1.1 mrg #zs0 at obio0 addr 0x01000000 level 12 flags 0x103 # sun4/100
264 1.1 mrg zstty0 at zs0 channel 0 # ttya
265 1.1 mrg zstty1 at zs0 channel 1 # ttyb
266 1.1 mrg
267 1.1 mrg zs1 at mainbus0 # sun4c
268 1.1 mrg zs1 at obio0 # sun4m
269 1.1 mrg #zs1 at obio0 addr 0xf0000000 level 12 flags 0x103 # sun4/200 and sun4/300
270 1.1 mrg #zs1 at obio0 addr 0x00000000 level 12 flags 0x103 # sun4/100
271 1.1 mrg kbd0 at zs1 channel 0 # keyboard
272 1.1 mrg ms0 at zs1 channel 1 # mouse
273 1.1 mrg
274 1.1 mrg #zs2 at obio0 addr 0xe0000000 level 12 flags 0x103 # sun4/300
275 1.1 mrg #zstty2 at zs2 channel 0 # ttyc
276 1.1 mrg #zstty3 at zs2 channel 1 # ttyd
277 1.1 mrg
278 1.1 mrg
279 1.1 mrg ## Magma Serial/Parallel driver
280 1.1 mrg #magma* at sbus? slot ? offset ?
281 1.1 mrg #mtty* at magma?
282 1.1 mrg #mbpp* at magma?
283 1.1 mrg
284 1.8 mrg ## PCMCIA serial interfaces
285 1.8 mrg #com* at pcmcia?
286 1.8 mrg #pcmcom* at pcmcia?
287 1.8 mrg #com* at pcmcom?
288 1.1 mrg
289 1.1 mrg #### Disk controllers and disks
290 1.1 mrg
291 1.1 mrg #
292 1.1 mrg
293 1.1 mrg ## The following flags may be set for the NCR53c94 based esp driver:
294 1.1 mrg ## bits 0-7: disable disconnect/reselect for the corresponding target
295 1.1 mrg ## bits 8-15: disable synchronous negotiation for target [bit-8]
296 1.1 mrg
297 1.1 mrg ## sun4/300, sun4c, sun4m on-board SCSI, and FSBE/S SBus SCSI cards.
298 1.1 mrg ## Both `dma' and `esp' are needed in all cases.
299 1.1 mrg ## Two kinds of additional SBus SCSI interfaces are available. One uses
300 1.1 mrg ## "esp at sbus" like the sun4c on-board; the other uses "esp at dma".
301 1.1 mrg
302 1.1 mrg ## sun4/300 SCSI - an NCR53c94 or equivalent behind
303 1.1 mrg ## an LSI Logic DMA controller
304 1.1 mrg
305 1.1 mrg #dma0 at obio0 addr 0xfa001000 level 4 # sun4/300
306 1.1 mrg #esp0 at obio0 addr 0xfa000000 level 4 flags 0x0000 # sun4/300
307 1.1 mrg
308 1.1 mrg dma0 at sbus0 slot ? offset ? # sun4c/sun4m
309 1.1 mrg esp0 at sbus0 slot ? offset ? flags 0x0000 # sun4c
310 1.1 mrg esp0 at dma0 flags 0x0000 # sun4m
311 1.1 mrg
312 1.1 mrg # FSBE/S SCSI
313 1.1 mrg dma* at sbus? slot ? offset ? # SBus
314 1.1 mrg esp* at sbus? slot ? offset ? flags 0x0000 # SBus (older proms)
315 1.1 mrg esp* at dma? flags 0x0000 # SBus
316 1.1 mrg
317 1.1 mrg scsibus* at esp?
318 1.1 mrg
319 1.1 mrg ## Qlogic ISP SBus SCSI Card
320 1.1 mrg isp* at sbus? slot ? offset ?
321 1.1 mrg scsibus* at isp?
322 1.1 mrg
323 1.1 mrg ## NCR5380-based "Sun SCSI 3" VME SCSI controller.
324 1.1 mrg ## This driver has several flags which may be enabled by OR'ing
325 1.1 mrg ## the values and using the "flags" directive.
326 1.1 mrg ## Valid flags are:
327 1.1 mrg ##
328 1.1 mrg ## 0x01 Use DMA (may be polled)
329 1.1 mrg ## 0x02 Use DMA completion interrupts
330 1.1 mrg ## 0x04 Allow disconnect/reselect
331 1.1 mrg ##
332 1.1 mrg ## E.g. the following would enable DMA, interrupts, and reselect:
333 1.10 drochner ## si0 at vme0 addr 0x200000 irq 3 vect 0x40 flags 0x07
334 1.1 mrg ##
335 1.1 mrg ## By default, DMA is enabled in the driver.
336 1.1 mrg
337 1.10 drochner #si0 at vme0 addr 0x200000 irq 2 vect 0x40
338 1.1 mrg #scsibus* at si?
339 1.1 mrg
340 1.1 mrg ## NCR5380-based "SCSI Weird" on-board SCSI interface found
341 1.1 mrg ## on sun4/100 systems. The flags are the same as the "si"
342 1.1 mrg ## controller. Note, while DMA is enabled by default, only
343 1.1 mrg ## polled DMA works at this time, and reselects do not work
344 1.1 mrg ## on this particular controller.
345 1.1 mrg
346 1.1 mrg #sw0 at obio0 addr 0x0a000000 level 3
347 1.1 mrg #scsibus* at sw?
348 1.1 mrg
349 1.8 mrg ## PCMCIA SCSI controllers
350 1.8 mrg #aic* at pcmcia?
351 1.8 mrg #scsibus* at aic?
352 1.8 mrg
353 1.8 mrg
354 1.1 mrg ## These entries find devices on all SCSI busses and assign
355 1.1 mrg ## unit numbers dynamically.
356 1.1 mrg sd* at scsibus? target ? lun ? # SCSI disks
357 1.1 mrg st* at scsibus? target ? lun ? # SCSI tapes
358 1.1 mrg cd* at scsibus? target ? lun ? # SCSI CD-ROMs
359 1.17 abs #ch* at scsibus? target ? lun ? # SCSI changer devices
360 1.1 mrg #ss* at scsibus? target ? lun ? # SCSI scanners
361 1.1 mrg #uk* at scsibus? target ? lun ? # unknown SCSI
362 1.1 mrg
363 1.1 mrg
364 1.1 mrg ## Xylogics 753 or 7053 VME SMD disk controllers and disks, found
365 1.1 mrg ## on sun4 systems.
366 1.10 drochner #xdc0 at vme0 addr 0xee80 irq 3 vect 0x44
367 1.10 drochner #xdc1 at vme0 addr 0xee90 irq 3 vect 0x45
368 1.10 drochner #xdc2 at vme0 addr 0xeea0 irq 3 vect 0x46
369 1.10 drochner #xdc3 at vme0 addr 0xeeb0 irq 3 vect 0x47
370 1.1 mrg #xd* at xdc? drive ?
371 1.1 mrg
372 1.1 mrg ## Xylogics 451 or 451 VME SMD disk controllers and disks, found
373 1.1 mrg ## on sun4 systems.
374 1.10 drochner #xyc0 at vme0 addr 0xee40 irq 3 vect 0x48
375 1.10 drochner #xyc1 at vme0 addr 0xee48 irq 3 vect 0x49
376 1.1 mrg #xy* at xyc? drive ?
377 1.1 mrg
378 1.1 mrg
379 1.1 mrg ## Floppy controller and drive found on SPARCstations.
380 1.1 mrg
381 1.1 mrg fdc0 at mainbus0 # sun4c controller
382 1.1 mrg fdc0 at obio0 # sun4m controller
383 1.1 mrg fd* at fdc0 # the drive itself
384 1.1 mrg
385 1.8 mrg ## PCMCIA IDE controllers
386 1.8 mrg #wdc* at pcmcia?
387 1.8 mrg #wd* at wdc?
388 1.8 mrg
389 1.1 mrg ## A disk-like interface to files. Can be used to create floppy, CD,
390 1.1 mrg ## miniroot images, etc.
391 1.1 mrg
392 1.1 mrg #pseudo-device vnd 4
393 1.1 mrg
394 1.1 mrg ## Concatenated and striped disks; with this, you can create a software-based
395 1.1 mrg ## disk array similar to a "RAID 0" setup. See ccd(4).
396 1.1 mrg
397 1.1 mrg #pseudo-device ccd 4
398 1.1 mrg
399 1.8 mrg ## RAIDframe disk driver: software RAID driver. See raid(4).
400 1.8 mrg
401 1.8 mrg #pseudo-device raid 4
402 1.8 mrg
403 1.1 mrg ## Memory disk device, used on boot floppies with compressed
404 1.1 mrg ## kernel-plus-root-disk images.
405 1.1 mrg
406 1.1 mrg #pseudo-device md 1
407 1.1 mrg
408 1.1 mrg
409 1.1 mrg #### Network interfaces
410 1.1 mrg
411 1.1 mrg ## LANCE Ethernet - an AMD 7990 LANCE behind specialized DMA glue
412 1.1 mrg ## Three flavors of additional SBus ethernets are available. One attaches
413 1.1 mrg ## directly like the sun4c on-board, one uses the ledma device like the
414 1.1 mrg ## sun4m on-board, and one uses the lebuffer device.
415 1.1 mrg
416 1.1 mrg #le0 at obio0 addr 0xf9000000 level 6 # sun4/300
417 1.1 mrg le0 at sbus0 slot ? offset ? # sun4c on-board
418 1.1 mrg ledma0 at sbus0 slot ? offset ? # sun4m on-board
419 1.1 mrg le0 at ledma0 # sun4m on-board
420 1.1 mrg le* at sbus? slot ? offset ? # SBus
421 1.1 mrg ledma* at sbus? slot ? offset ? # SBus
422 1.1 mrg le* at ledma? # SBus
423 1.1 mrg lebuffer0 at sbus? slot ? offset ? # SBus
424 1.1 mrg le0 at lebuffer? # SBus
425 1.1 mrg lebuffer* at sbus? slot ? offset ? # SBus
426 1.1 mrg le* at lebuffer? # SBus
427 1.1 mrg
428 1.1 mrg
429 1.1 mrg ## sun4/100 and sun4/200 Ethernet - an Intel 82586 on-board
430 1.1 mrg ## or on a Multibus/VME card.
431 1.1 mrg #ie0 at obio0 addr 0xf6000000 level 6 # sun4/200 on-board
432 1.1 mrg #ie0 at obio0 addr 0x06000000 level 6 # sun4/100 on-board
433 1.10 drochner #ie1 at vme0 addr 0xe88000 irq 3 vect 0x75 # VME
434 1.10 drochner #ie2 at vme0 addr 0x31ff02 irq 3 vect 0x76 # VME
435 1.10 drochner #ie3 at vme0 addr 0x35ff02 irq 3 vect 0x77 # VME
436 1.10 drochner #ie4 at vme0 addr 0x2dff02 irq 3 vect 0x7c # VME
437 1.1 mrg
438 1.8 mrg ## qec/be, qec/hme
439 1.8 mrg qec* at sbus? slot ? offset ?
440 1.8 mrg be* at qec?
441 1.8 mrg qe* at qec?
442 1.8 mrg
443 1.8 mrg # midway ATM
444 1.8 mrg en0 at sbus? slot ? offset ?
445 1.8 mrg
446 1.8 mrg # PCMCIA ethernet devices
447 1.8 mrg #ep* at pcmcia?
448 1.8 mrg #mbe* at pcmcia?
449 1.8 mrg #ne* at pcmcia?
450 1.8 mrg #sm* at pcmcia?
451 1.8 mrg
452 1.8 mrg # MII/PHY support
453 1.8 mrg #exphy* at mii? phy ? # 3Com internal PHYs
454 1.8 mrg #icsphy* at mii? phy ? # Integrated Circuit Systems ICS1890
455 1.8 mrg #inphy* at mii? phy ? # Intel 82555 PHYs
456 1.8 mrg #lxtphy* at mii? phy ? # Level One LXT-970 PHYs
457 1.8 mrg #nsphy* at mii? phy ? # NS83840 PHYs
458 1.8 mrg #qsphy* at mii? phy ? # Quality Semiconductor QS6612 PHYs
459 1.8 mrg #sqphy* at mii? phy ? # Seeq 80220/80221/80223 PHYs
460 1.8 mrg #tlphy* at mii? phy ? # ThunderLAN PHYs
461 1.8 mrg #ukphy* at mii? phy ? # generic unknown PHYs
462 1.8 mrg
463 1.1 mrg ## Loopback network interface; required
464 1.1 mrg pseudo-device loop
465 1.1 mrg
466 1.1 mrg ## SLIP and CSLIP interfaces, for IP over a serial line.
467 1.1 mrg pseudo-device sl 2
468 1.1 mrg
469 1.1 mrg ## PPP, the successor to SLIP. See pppd(8).
470 1.17 abs #pseudo-device ppp 2
471 1.1 mrg
472 1.1 mrg ## Starmode Radio IP, a special hardware network device.
473 1.1 mrg #pseudo-device strip 1
474 1.1 mrg
475 1.1 mrg ## Network "tunnel" device, allowing protocol stacks to run in the userland.
476 1.1 mrg ## This is used by the third-party user-mode "ppp" program, and others.
477 1.1 mrg #pseudo-device tun 4
478 1.1 mrg
479 1.8 mrg ## Generic L3 over IP tunnel
480 1.8 mrg #pseudo-device gre 2 # generic L3 over IP tunnel
481 1.8 mrg
482 1.1 mrg ## Berkeley Packet Filter, required to run RARPD. A generic C-language
483 1.1 mrg ## interface that allows selective examining of incoming packets.
484 1.1 mrg #pseudo-device bpfilter 8
485 1.1 mrg
486 1.1 mrg ## IP Filter, used in firewall and NAT applications. See ipnat(8) for
487 1.1 mrg ## one example of the use of the IP Filter.
488 1.1 mrg #pseudo-device ipfilter
489 1.1 mrg
490 1.1 mrg
491 1.1 mrg #### Audio and video devices
492 1.1 mrg
493 1.1 mrg ## /dev/audio support (`audioamd' plus `audio')
494 1.1 mrg ##
495 1.1 mrg #audioamd0 at mainbus0 # sun4c
496 1.1 mrg #audioamd0 at obio0 # sun4m
497 1.1 mrg #audioamd0 at sbus0 slot ? offset ? # sun4m
498 1.1 mrg #audio* at audioamd0
499 1.1 mrg
500 1.8 mrg #audiocs0 at sbus0 slot ? offset ? # SUNW,CS4231
501 1.8 mrg #audio* at audiocs0
502 1.8 mrg
503 1.1 mrg
504 1.1 mrg ## Sun "bwtwo" black and white framebuffer, found on sun4, sun4c, and sun4m
505 1.1 mrg ## systems. If your sun4 system has a cgfour installed in the P4 slot,
506 1.1 mrg ## the P4 entries for "bwtwo" will attach to the overlay plane of the
507 1.1 mrg ## "cgfour".
508 1.1 mrg
509 1.1 mrg bwtwo0 at sbus0 slot ? offset ? # sun4c and sun4m
510 1.1 mrg bwtwo* at sbus? slot ? offset ? #
511 1.1 mrg #bwtwo0 at obio0 addr 0xfd000000 level 4 # sun4/200
512 1.1 mrg #bwtwo0 at obio0 addr 0xfb300000 level 4 # sun4/300 in P4 slot
513 1.1 mrg #bwtwo0 at obio0 addr 0x0b300000 level 4 # sun4/100 in P4 slot
514 1.1 mrg
515 1.1 mrg ## Sun "cgtwo" VME color framebuffer
516 1.10 drochner #cgtwo0 at vme0 addr 0x400000 irq ? vect 0xa8
517 1.1 mrg
518 1.1 mrg ## Sun "cgthree" Sbus color framebuffer
519 1.1 mrg cgthree0 at sbus? slot ? offset ?
520 1.1 mrg cgthree* at sbus? slot ? offset ?
521 1.1 mrg #cgthree0 at obio? slot ? offset ? # sun4m
522 1.1 mrg
523 1.1 mrg ## Sun "cgfour" color framebuffer with overlay plane. See above comment
524 1.1 mrg ## regarding overlay plane.
525 1.1 mrg #cgfour0 at obio0 addr 0xfb300000 level 4 # sun4/300 P4
526 1.1 mrg #cgfour0 at obio0 addr 0x0b300000 level 4 # sun4/100 P4
527 1.1 mrg
528 1.1 mrg ## Sun "cgsix" accelerated color framebuffer.
529 1.1 mrg cgsix0 at sbus? slot ? offset ?
530 1.1 mrg cgsix* at sbus? slot ? offset ?
531 1.1 mrg #cgsix0 at obio0 addr 0xfb000000 level 4 # sun4/300 P4
532 1.1 mrg #cgsix0 at obio0 addr 0x0b000000 level 4 # sun4/100 P4
533 1.1 mrg
534 1.1 mrg ## Sun "cgeight" 24-bit framebuffer
535 1.1 mrg #cgeight0 at obio0 addr 0xfb300000 level 4 # sun4/300 P4
536 1.1 mrg #cgeight0 at obio0 addr 0x0b300000 level 4 # sun4/100 P4
537 1.1 mrg
538 1.1 mrg ## Sun "tcx" accelerated color framebuffer.
539 1.1 mrg tcx0 at sbus? slot ? offset ?
540 1.1 mrg tcx* at sbus? slot ? offset ?
541 1.1 mrg
542 1.1 mrg # Sun "cgfourteen" accelerated 24-bit framebuffer.
543 1.1 mrg cgfourteen0 at obio0 # sun4m
544 1.1 mrg
545 1.1 mrg
546 1.1 mrg #### Other device configuration
547 1.1 mrg
548 1.1 mrg ## Pseudo ttys, required for network logins and programs like screen.
549 1.1 mrg
550 1.22 abs pseudo-device pty 2 # pseudo-terminals (Sysinst needs two)
551 1.1 mrg
552 1.1 mrg ## Random device, used to implement /dev/random (a source of random noise),
553 1.1 mrg ## and generate randomness for some kernel formulae.
554 1.1 mrg
555 1.17 abs #pseudo-device rnd
556