Home | History | Annotate | Line # | Download | only in conf
INSTALL revision 1.99.2.1
      1  1.99.2.1  pgoyette #	$NetBSD: INSTALL,v 1.99.2.1 2018/09/06 06:55:41 pgoyette Exp $
      2       1.1       mrg #
      3       1.8       mrg # from: NetBSD: GENERIC,v 1.84 1999/06/06 13:00:03 mrg Exp
      4       1.1       mrg #
      5       1.1       mrg # floppy install kernel.  try to keep this in sync with GENERIC but
      6       1.1       mrg # leave as much disabled as possible.
      7       1.1       mrg 
      8       1.1       mrg include "arch/sparc/conf/std.sparc"
      9      1.34    atatat 
     10      1.34    atatat #options 	INCLUDE_CONFIG_FILE	# embed config file in kernel binary
     11      1.20       abs 
     12      1.28     lukem makeoptions	COPTS="-Os"		# Optimise for space. Implies -O2
     13       1.1       mrg 
     14       1.1       mrg maxusers	32
     15       1.1       mrg 
     16       1.1       mrg # Enable the hooks used for initializing the root memory-disk.
     17       1.1       mrg options 	MEMORY_DISK_HOOKS
     18       1.1       mrg options 	MEMORY_DISK_IS_ROOT	# force root on memory disk
     19       1.1       mrg options 	MEMORY_DISK_SERVER=0	# no userspace memory disk support
     20      1.23        pk ## The miniroot size must be kept in sync manually with the size of
     21      1.23        pk ## the `ramdisk' image (which is built in distrib/sparc/ramdisk).
     22      1.96     joerg options 	MEMORY_DISK_ROOT_SIZE=2000	# size of memory disk, in blocks
     23      1.65       jym options 	MEMORY_DISK_RBFLAGS=RB_SINGLE	# boot in single-user mode
     24       1.1       mrg 
     25      1.77   hannken pseudo-device	md			# memory disk device (ramdisk)
     26       1.1       mrg 
     27       1.1       mrg ## System kernel configuration.  See options(4) for more detail.
     28       1.1       mrg 
     29       1.9       mrg 
     30       1.1       mrg # Options for variants of the Sun SPARC architecure.
     31       1.1       mrg # We currently support three architecture types; at least one is required.
     32      1.24        pk options 	SUN4		# sun4/100, sun4/200, sun4/300
     33       1.1       mrg options 	SUN4C		# sun4c - SS1, 1+, 2, ELC, SLC, IPC, IPX, etc.
     34       1.1       mrg options 	SUN4M		# sun4m - SS10, SS20, Classic, etc.
     35       1.1       mrg 
     36      1.25        pk options 	SUN4_MMU3L	# 3-level MMU on sun4/400
     37       1.1       mrg 
     38       1.1       mrg ## System options specific to the sparc machine type
     39       1.1       mrg 
     40       1.1       mrg # Blink the power LED on some machines to indicate the system load.
     41       1.1       mrg #options 	BLINK
     42       1.1       mrg 
     43      1.64  macallan # wscons stuff
     44      1.82  macallan #options 	WSEMUL_SUN
     45      1.82  macallan options 	WSEMUL_VT100
     46      1.83       abs options 	WSDISPLAY_DEFAULTSCREENS=1
     47      1.83       abs #options 	WSDISPLAY_COMPAT_USL		# wsconscfg VT handling
     48      1.66       jdc options 	WSDISPLAY_COMPAT_RAWKBD
     49      1.66       jdc options 	WSDISPLAY_CUSTOM_OUTPUT
     50      1.66       jdc options 	WS_DEFAULT_FG=WSCOL_BLACK
     51      1.66       jdc options 	WS_DEFAULT_BG=WSCOL_LIGHT_WHITE
     52      1.66       jdc options 	WS_KERNEL_FG=WSCOL_GREEN
     53      1.66       jdc options 	WS_KERNEL_BG=WSCOL_LIGHT_WHITE
     54      1.92  macallan options 	FONT_GALLANT12x22	# the console font
     55      1.92  macallan options 	FONT_BOLD8x16		# a somewhat smaller font
     56      1.64  macallan 
     57       1.1       mrg #### System options that are the same for all ports
     58       1.1       mrg 
     59       1.1       mrg ## Root device configuration: change the ?'s if you are going to use a
     60       1.1       mrg ## nonstandard root partition (other than where the kernel is booted from)
     61       1.1       mrg ## and/or nonstandard root type (not ffs or nfs).  Normally this can be
     62       1.1       mrg ## automagically determined at boot time.
     63       1.1       mrg 
     64       1.1       mrg config		netbsd	root on ? type ?
     65       1.1       mrg 
     66       1.1       mrg ## System call tracing (see ktrace(1)).
     67       1.1       mrg #options 	KTRACE
     68       1.1       mrg 
     69       1.1       mrg ## System V compatible IPC subsystem.  (msgctl(2), semctl(2), and shmctl(2))
     70       1.1       mrg #options 	SYSVMSG		# System V message queues
     71       1.1       mrg #options 	SYSVSEM		# System V semaphores
     72       1.1       mrg #options 	SYSVSHM		# System V shared memory
     73       1.1       mrg 
     74      1.37     lukem options 	USERCONF	# userconf(4) support
     75      1.66       jdc options 	PIPE_SOCKETPAIR		# smaller, but slower pipe(2)
     76      1.42    atatat #options 	SYSCTL_INCLUDE_DESCR	# Include sysctl descriptions in kernel
     77       1.1       mrg 
     78      1.35     lukem ## NFS boot options; tries DHCP/BOOTP then BOOTPARAM
     79       1.1       mrg options 	NFS_BOOT_BOOTPARAM
     80       1.1       mrg #options 	NFS_BOOT_BOOTP
     81      1.31     lukem options 	NFS_BOOT_DHCP
     82       1.1       mrg 
     83       1.1       mrg #### Debugging options
     84       1.1       mrg 
     85       1.1       mrg ## The DDB in-kernel debugger runs at panic (unless DDB_ONPANIC=0), or at
     86       1.1       mrg ## serial console break or keyboard reset, where the PROM would normally
     87       1.1       mrg ## intercept.  DDB_HISTORY_SIZE adds up/down arrow command history.
     88      1.17       abs #options 	DDB			# kernel dynamic debugger
     89       1.1       mrg #options 	DDB_HISTORY_SIZE=100	# enable history editing in DDB
     90      1.89  szptvlfn #options 	DDB_ONPANIC=1		# see also sysctl(7): `ddb.onpanic'
     91       1.1       mrg 
     92       1.1       mrg ## You may also use gdb, on another computer connected to this machine over
     93      1.27     lukem ## a serial port.  Both KGDB_DEV and KGDB_DEVRATE should be specified;
     94      1.27     lukem ## KGDB_DEV is a dev_t encoded device number of the serial port to use.
     95       1.1       mrg ## (0xc01 = ttya, 0xc02 = ttyb.)
     96      1.27     lukem #options 	KGDB			# support for kernel gdb
     97      1.27     lukem #options 	KGDB_DEV=0xc01		# kgdb device number (this is `ttyb')
     98      1.27     lukem #options 	KGDB_DEVRATE=38400	# baud rate
     99       1.1       mrg 
    100       1.1       mrg 
    101       1.1       mrg ## Compile the kernel with debugging symbols (`netbsd.gdb' is the debug file),
    102       1.1       mrg ## such that gdb(1) can be used on a kernel coredump.
    103       1.1       mrg 
    104      1.28     lukem #makeoptions	DEBUG="-g"
    105       1.1       mrg 
    106       1.1       mrg 
    107       1.1       mrg ## Adds code to the kernel that does internal consistency checks, and will
    108       1.1       mrg ## cause the kernel to panic if corruption of internal data structures
    109       1.1       mrg ## is detected.
    110       1.1       mrg #options 	DIAGNOSTIC	# extra kernel sanity checking
    111       1.1       mrg 
    112       1.1       mrg ## Enable (possibly expensive) debugging code that may also display messages
    113       1.1       mrg ## on the system console
    114       1.1       mrg #options 	DEBUG
    115      1.13  augustss 
    116      1.13  augustss #options 	MIIVERBOSE	# verbose PHY autoconfig messages
    117       1.1       mrg 
    118       1.1       mrg ## Make SCSI error messages more verbose when explaining their meanings.
    119       1.1       mrg #options 	SCSIVERBOSE
    120       1.1       mrg 
    121       1.1       mrg ## `INSECURE' turns off the kernel security level (securelevel = 0 always).
    122       1.1       mrg ## This allows writing to /dev/mem, loading kernel modules while multi-user,
    123       1.1       mrg ## and other insecurities good only for development work.  Do not use this
    124       1.1       mrg ## option on a production machine.
    125       1.1       mrg options 	INSECURE
    126       1.1       mrg 
    127       1.1       mrg ## `FDSCRIPTS' allows non-readable but executable scripts by providing a
    128       1.1       mrg ## pre-opened opaque file to the script interpreter.  `SETUIDSCRIPTS',
    129       1.1       mrg ## which implies FDSCRIPTS, allows scripts to be set-user-id using the same
    130       1.1       mrg ## opaque file mechanism.  Perl calls this "secure setuid scripts."
    131       1.1       mrg 
    132       1.1       mrg #options 	FDSCRIPTS
    133       1.1       mrg #options 	SETUIDSCRIPTS
    134       1.1       mrg 
    135       1.1       mrg ## Options for compatibility with previous releases foreign system binaries.
    136       1.1       mrg ## In the cases of COMPAT_SUNOS and COMPAT_SVR4, you may need to set up
    137       1.1       mrg ## additional user-level utilities or system configuration files. See
    138       1.1       mrg ## compat_sunos(8) and compat_svr4(8).
    139       1.1       mrg 
    140      1.98       mrg #include 	"conf/compat_netbsd10.config"
    141       1.1       mrg #options 	COMPAT_SUNOS	# SunOS 4.x binary compatibility
    142       1.1       mrg #options 	COMPAT_SVR4	# SunOS 5.x binary compatibility
    143      1.66       jdc options 	COMPAT_BSDPTY	# /dev/[pt]ty?? ptys.
    144       1.1       mrg 
    145       1.1       mrg ## File systems.  You probably need at least one of FFS or NFS.
    146       1.1       mrg file-system	FFS		# Berkeley Fast Filesystem
    147       1.1       mrg file-system	NFS		# Sun NFS-compatible filesystem client
    148      1.15        pk #file-system	KERNFS		# kernel data-structure filesystem
    149       1.1       mrg #file-system	NULLFS		# NULL layered filesystem
    150      1.23        pk file-system	MFS		# memory-based filesystem
    151       1.1       mrg #file-system	FDESC		# user file descriptor filesystem
    152       1.1       mrg #file-system	UMAPFS		# uid/gid remapping filesystem
    153       1.1       mrg #file-system	LFS		# Log-based filesystem (still experimental)
    154       1.1       mrg #file-system	PROCFS		# /proc
    155       1.1       mrg file-system	CD9660		# ISO 9660 + Rock Ridge file system
    156       1.1       mrg #file-system	UNION		# union file system
    157       1.1       mrg #file-system	MSDOSFS		# MS-DOS FAT filesystem(s).
    158      1.50  christos #file-system	PTYFS		# /dev/pts/N support
    159       1.1       mrg 
    160      1.21       abs ## File system options
    161       1.1       mrg #options 	NFSSERVER	# Sun NFS-compatible filesystem server
    162      1.78    bouyer #options 	QUOTA		# legacy UFS quotas
    163      1.78    bouyer #options 	QUOTA2		# new, in-filesystem UFS quotas
    164       1.1       mrg #options 	FFS_EI		# FFS Endian Independent support
    165      1.58      yamt #options 	NFS_V2_ONLY	# Exclude NFS3 code to save space
    166      1.51   tsutsui options 	FFS_NO_SNAPSHOT	# No FFS snapshot support
    167      1.80  dholland options 	WAPBL		# File system journaling support
    168       1.1       mrg 
    169       1.1       mrg ## Network protocol support.  In most environments, INET is required.
    170       1.1       mrg options 	INET		# IP (Internet Protocol) v4
    171       1.1       mrg #options 	GATEWAY		# packet forwarding ("router switch")
    172       1.1       mrg #options 	MROUTING	# packet forwarding of multicast packets
    173      1.43      manu #options 	PIM		# Protocol Independent Multicast
    174       1.1       mrg #options 	NETATALK	# AppleTalk (over Ethernet) protocol
    175       1.1       mrg #options 	NTP		# Network Time Protocol in-kernel support
    176       1.1       mrg #options 	PPS_SYNC	# Add serial line synchronization for NTP
    177       1.1       mrg #options 	PPP_BSDCOMP	# Add BSD compression to ppp device
    178       1.1       mrg #options 	PPP_DEFLATE	# Add deflate (libz) compression to ppp device
    179       1.1       mrg #options 	PPP_FILTER	# Add active filters for ppp (via bpf)
    180      1.26       abs #options 	TCP_DEBUG	# Record last TCP_NDEBUG packets with SO_DEBUG
    181       1.1       mrg 
    182       1.1       mrg 
    183       1.1       mrg #### Main bus and CPU .. all systems.
    184       1.1       mrg mainbus0 at root
    185       1.1       mrg cpu0	at mainbus0
    186       1.1       mrg 
    187      1.84  macallan #### SX rendering engine found in SS20 and SS10SX
    188      1.84  macallan sx0	at mainbus0
    189      1.84  macallan 
    190       1.1       mrg #### Bus types found on SPARC systems.
    191       1.1       mrg 
    192       1.1       mrg sbus0	at mainbus0				# sun4c
    193       1.1       mrg obio0	at mainbus0				# sun4 and sun4m
    194      1.24        pk sparcvme0	at mainbus0				# sun4
    195       1.1       mrg iommu0	at mainbus0				# sun4m
    196       1.1       mrg sbus0	at iommu0				# sun4m
    197      1.10  drochner sparcvme0	at iommu0				# sun4m
    198      1.24        pk vme0	at sparcvme0			# mi VME attachment
    199       1.1       mrg 
    200       1.1       mrg ## SBus expander box
    201       1.9       mrg xbox*	at sbus? slot ? offset ?
    202       1.9       mrg sbus*	at xbox?
    203       1.1       mrg 
    204       1.8       mrg ## SBus to PCMCIA bridge
    205       1.8       mrg # Currently enabling nell* with audioamd* causes panic at attach
    206       1.8       mrg #nell*	at sbus? slot ? offset ?		# PCMCIA bridge
    207       1.8       mrg #pcmcia*	at nell?
    208       1.8       mrg 
    209       1.1       mrg #### Standard system devices -- all required for a given architecture
    210       1.1       mrg 
    211       1.1       mrg ## Auxiliary system registers on sun4c and sun4m
    212       1.1       mrg auxreg0	at mainbus0				# sun4c
    213       1.1       mrg auxreg0	at obio0				# sun4m
    214       1.1       mrg 
    215       1.1       mrg ## Power status and control register on Sun4m systems
    216       1.1       mrg power0	at obio0
    217       1.1       mrg 
    218       1.1       mrg ## Mostek clock found on 4/300, sun4c, and sun4m systems.
    219       1.1       mrg ## The Mostek clock NVRAM is the "eeprom" on sun4/300 systems.
    220       1.1       mrg clock0	at mainbus0				# sun4c
    221       1.1       mrg clock0	at obio0				# sun4m
    222      1.24        pk clock0	at obio0 addr 0xf2000000		# sun4/300
    223       1.1       mrg 
    224       1.1       mrg ## Intersil clock found on 4/100 and 4/200 systems.
    225      1.24        pk oclock0	at obio0 addr 0xf3000000		# sun4/200
    226      1.24        pk oclock0	at obio0 addr 0x03000000		# sun4/100
    227       1.1       mrg 
    228       1.1       mrg ## Memory error registers.
    229       1.1       mrg memreg0	at mainbus0				# sun4c
    230       1.1       mrg memreg0	at obio0				# sun4m
    231      1.24        pk memreg0	at obio0 addr 0xf4000000		# sun4/200 and sun4/300
    232      1.24        pk memreg0	at obio0 addr 0x04000000		# sun4/100
    233       1.1       mrg 
    234       1.8       mrg ## ECC memory control
    235       1.8       mrg eccmemctl0 at mainbus0				# sun4m
    236       1.8       mrg 
    237       1.1       mrg ## Timer chip found on 4/300, sun4c, and sun4m systems.
    238       1.1       mrg timer0	at mainbus0				# sun4c
    239       1.1       mrg timer0	at obio0				# sun4m
    240      1.24        pk timer0	at obio0 addr 0xef000000		# sun4/300
    241       1.1       mrg 
    242       1.1       mrg ## EEPROM found on 4/100 and 4/200 systems.  Note that the 4/300
    243       1.1       mrg ## doesn't use this driver; the `EEPROM' is in the NVRAM on the
    244       1.1       mrg ## Mostek clock chip on 4/300 systems.
    245      1.24        pk eeprom0	at obio0 addr 0xf2000000		# sun4/200
    246      1.24        pk eeprom0	at obio0 addr 0x02000000		# sun4/100
    247       1.1       mrg 
    248       1.1       mrg 
    249       1.1       mrg #### Serial port configuration
    250       1.1       mrg 
    251       1.1       mrg ## Zilog 8530 serial chips.  Each has two-channels.
    252       1.1       mrg ## zs0 is ttya and ttyb.  zs1 is the keyboard and mouse.
    253       1.1       mrg zs0	at mainbus0					# sun4c
    254       1.1       mrg zs0	at obio0					# sun4m
    255      1.24        pk zs0	at obio0 addr 0xf1000000 level 12 flags 0x103	# sun4/200 and sun4/300
    256      1.24        pk zs0	at obio0 addr 0x01000000 level 12 flags 0x103	# sun4/100
    257       1.1       mrg 
    258       1.1       mrg zs1	at mainbus0					# sun4c
    259       1.1       mrg zs1	at obio0					# sun4m
    260      1.24        pk zs1	at obio0 addr 0xf0000000 level 12 flags 0x103	# sun4/200 and sun4/300
    261      1.24        pk zs1	at obio0 addr 0x00000000 level 12 flags 0x103	# sun4/100
    262       1.1       mrg 
    263      1.64  macallan zs2	at obio0 addr 0xe0000000 level 12		# sun4/300
    264      1.64  macallan 
    265      1.64  macallan zstty*	at zs?
    266       1.1       mrg 
    267      1.64  macallan # these are for wscons
    268      1.64  macallan kbd0	at zstty?
    269      1.64  macallan ms0	at zstty?
    270      1.64  macallan wskbd*	at wskbddev?
    271      1.64  macallan wsmouse* 	at wsmousedev?
    272       1.1       mrg 
    273       1.1       mrg ## Magma Serial/Parallel driver
    274       1.1       mrg #magma*	at sbus? slot ? offset ?
    275       1.1       mrg #mtty*	at magma?
    276       1.1       mrg #mbpp*	at magma?
    277       1.1       mrg 
    278       1.8       mrg ## PCMCIA serial interfaces
    279       1.8       mrg #com*	at pcmcia?
    280       1.8       mrg #pcmcom*	at pcmcia?
    281       1.8       mrg #com*	at pcmcom?
    282       1.1       mrg 
    283       1.1       mrg #### Disk controllers and disks
    284       1.1       mrg 
    285       1.1       mrg #
    286       1.1       mrg 
    287       1.1       mrg ## The following flags may be set for the NCR53c94 based esp driver:
    288       1.1       mrg ##	bits 0-7:  disable disconnect/reselect for the corresponding target
    289       1.1       mrg ##	bits 8-15: disable synchronous negotiation for target [bit-8]
    290       1.1       mrg 
    291       1.1       mrg ## sun4/300, sun4c, sun4m on-board SCSI, and FSBE/S SBus SCSI cards.
    292       1.1       mrg ## Both `dma' and `esp' are needed in all cases.
    293       1.1       mrg ## Two kinds of additional SBus SCSI interfaces are available.  One uses
    294       1.1       mrg ## "esp at sbus" like the sun4c on-board; the other uses "esp at dma".
    295       1.1       mrg 
    296       1.1       mrg ## sun4/300 SCSI - an NCR53c94 or equivalent behind
    297       1.1       mrg ## an LSI Logic DMA controller
    298       1.1       mrg 
    299      1.24        pk dma0	at obio0 addr 0xfa001000 level 4		# sun4/300
    300      1.24        pk esp0	at obio0 addr 0xfa000000 level 4 flags 0x0000	# sun4/300
    301       1.1       mrg 
    302       1.1       mrg dma0	at sbus0 slot ? offset ?			# sun4c/sun4m
    303       1.1       mrg esp0	at sbus0 slot ? offset ? flags 0x0000		# sun4c
    304       1.1       mrg esp0	at dma0 flags 0x0000				# sun4m
    305       1.1       mrg 
    306       1.1       mrg # FSBE/S SCSI
    307       1.1       mrg dma*	at sbus? slot ? offset ?			# SBus
    308       1.1       mrg esp*	at sbus? slot ? offset ? flags 0x0000		# SBus (older proms)
    309       1.1       mrg esp*	at dma? flags 0x0000				# SBus
    310       1.1       mrg 
    311       1.1       mrg scsibus* at esp?
    312       1.1       mrg 
    313       1.1       mrg ## Qlogic ISP SBus SCSI Card
    314       1.1       mrg isp*	at sbus? slot ? offset ?
    315       1.1       mrg scsibus* at isp?
    316       1.1       mrg 
    317       1.1       mrg ## NCR5380-based "Sun SCSI 3" VME SCSI controller.
    318       1.1       mrg ## This driver has several flags which may be enabled by OR'ing
    319       1.1       mrg ## the values and using the "flags" directive.
    320       1.1       mrg ## Valid flags are:
    321       1.1       mrg ##
    322       1.1       mrg ##	0x01		Use DMA (may be polled)
    323       1.1       mrg ##	0x02		Use DMA completion interrupts
    324       1.1       mrg ##	0x04		Allow disconnect/reselect
    325       1.1       mrg ##
    326       1.1       mrg ## E.g. the following would enable DMA, interrupts, and reselect:
    327      1.10  drochner ## si0	at vme0 addr 0x200000 irq 3 vect 0x40 flags 0x07
    328       1.1       mrg ##
    329       1.1       mrg ## By default, DMA is enabled in the driver.
    330       1.1       mrg 
    331      1.24        pk si0	at vme0 addr 0x200000 irq 2 vect 0x40
    332      1.24        pk scsibus* at si?
    333       1.1       mrg 
    334       1.1       mrg ## NCR5380-based "SCSI Weird" on-board SCSI interface found
    335       1.1       mrg ## on sun4/100 systems.  The flags are the same as the "si"
    336       1.1       mrg ## controller.  Note, while DMA is enabled by default, only
    337       1.1       mrg ## polled DMA works at this time, and reselects do not work
    338       1.1       mrg ## on this particular controller.
    339       1.1       mrg 
    340      1.24        pk sw0	at obio0 addr 0x0a000000 level 3
    341      1.24        pk scsibus* at sw?
    342       1.1       mrg 
    343       1.8       mrg ## PCMCIA SCSI controllers
    344       1.8       mrg #aic*	at pcmcia?
    345       1.8       mrg #scsibus* at aic?
    346       1.8       mrg 
    347       1.8       mrg 
    348       1.1       mrg ## These entries find devices on all SCSI busses and assign
    349       1.1       mrg ## unit numbers dynamically.
    350       1.1       mrg sd*	at scsibus? target ? lun ?		# SCSI disks
    351       1.1       mrg st*	at scsibus? target ? lun ?		# SCSI tapes
    352       1.1       mrg cd*	at scsibus? target ? lun ?		# SCSI CD-ROMs
    353      1.17       abs #ch*	at scsibus? target ? lun ?		# SCSI changer devices
    354       1.1       mrg #ss*	at scsibus? target ? lun ?		# SCSI scanners
    355       1.1       mrg #uk*	at scsibus? target ? lun ?		# unknown SCSI
    356       1.1       mrg 
    357       1.1       mrg 
    358       1.1       mrg ## Xylogics 753 or 7053 VME SMD disk controllers and disks, found
    359       1.1       mrg ## on sun4 systems.
    360      1.24        pk xdc0	at vme0 addr 0xee80 irq 3 vect 0x44
    361      1.24        pk xdc1	at vme0 addr 0xee90 irq 3 vect 0x45
    362      1.24        pk xdc2	at vme0 addr 0xeea0 irq 3 vect 0x46
    363      1.24        pk xdc3	at vme0 addr 0xeeb0 irq 3 vect 0x47
    364      1.24        pk xd*	at xdc? drive ?
    365       1.1       mrg 
    366       1.1       mrg ## Xylogics 451 or 451 VME SMD disk controllers and disks, found
    367       1.1       mrg ## on sun4 systems.
    368      1.24        pk xyc0	at vme0 addr 0xee40 irq 3 vect 0x48
    369      1.24        pk xyc1	at vme0 addr 0xee48 irq 3 vect 0x49
    370      1.24        pk xy*	at xyc? drive ?
    371       1.1       mrg 
    372       1.1       mrg 
    373       1.1       mrg ## Floppy controller and drive found on SPARCstations.
    374       1.1       mrg 
    375       1.1       mrg fdc0	at mainbus0				# sun4c controller
    376       1.1       mrg fdc0	at obio0				# sun4m controller
    377       1.1       mrg fd*	at fdc0					# the drive itself
    378       1.1       mrg 
    379       1.8       mrg ## PCMCIA IDE controllers
    380       1.8       mrg #wdc*	at pcmcia?
    381       1.8       mrg #wd*	at wdc?
    382       1.8       mrg 
    383       1.1       mrg ## A disk-like interface to files.  Can be used to create floppy, CD,
    384       1.1       mrg ## miniroot images, etc.
    385       1.1       mrg 
    386      1.54      cube #pseudo-device	vnd	
    387       1.1       mrg 
    388       1.1       mrg ## Concatenated and striped disks; with this, you can create a software-based
    389       1.1       mrg ## disk array similar to a "RAID 0" setup.  See ccd(4).
    390       1.1       mrg 
    391      1.86  christos #pseudo-device	ccd
    392       1.1       mrg 
    393       1.8       mrg ## RAIDframe disk driver: software RAID driver.  See raid(4).
    394       1.8       mrg 
    395      1.87  christos #pseudo-device	raid
    396       1.8       mrg 
    397       1.1       mrg ## Memory disk device, used on boot floppies with compressed
    398       1.1       mrg ## kernel-plus-root-disk images.
    399       1.1       mrg 
    400      1.77   hannken #pseudo-device	md	
    401       1.1       mrg 
    402       1.1       mrg 
    403       1.1       mrg #### Network interfaces
    404       1.1       mrg 
    405       1.1       mrg ## LANCE Ethernet - an AMD 7990 LANCE behind specialized DMA glue
    406       1.1       mrg ## Three flavors of additional SBus ethernets are available.  One attaches
    407       1.1       mrg ## directly like the sun4c on-board, one uses the ledma device like the
    408       1.1       mrg ## sun4m on-board, and one uses the lebuffer device.
    409       1.1       mrg 
    410      1.24        pk le0		at obio0 addr 0xf9000000 level 6	# sun4/300
    411       1.1       mrg le0		at sbus0 slot ? offset ?		# sun4c on-board
    412       1.1       mrg ledma0		at sbus0 slot ? offset ?		# sun4m on-board
    413       1.1       mrg le0		at ledma0				# sun4m on-board
    414       1.1       mrg le*		at sbus? slot ? offset ?		# SBus
    415       1.1       mrg ledma*		at sbus? slot ? offset ?		# SBus
    416       1.1       mrg le*		at ledma?				# SBus
    417       1.1       mrg lebuffer0	at sbus? slot ? offset ?		# SBus
    418       1.1       mrg le0		at lebuffer?				# SBus
    419       1.1       mrg lebuffer*	at sbus? slot ? offset ?		# SBus
    420       1.1       mrg le*		at lebuffer?				# SBus
    421       1.1       mrg 
    422       1.1       mrg 
    423       1.1       mrg ## sun4/100 and sun4/200 Ethernet - an Intel 82586 on-board
    424       1.1       mrg ## or on a Multibus/VME card.
    425      1.24        pk ie0	at obio0 addr 0xf6000000 level 6		# sun4/200 on-board
    426      1.24        pk ie0	at obio0 addr 0x06000000 level 6		# sun4/100 on-board
    427      1.24        pk ie1	at vme0 addr 0xe88000 irq 3 vect 0x75		# VME
    428      1.24        pk ie2	at vme0 addr 0x31ff02 irq 3 vect 0x76		# VME
    429      1.24        pk ie3	at vme0 addr 0x35ff02 irq 3 vect 0x77		# VME
    430      1.24        pk ie4	at vme0 addr 0x2dff02 irq 3 vect 0x7c		# VME
    431       1.1       mrg 
    432       1.8       mrg ## qec/be, qec/hme
    433       1.8       mrg qec*		at sbus? slot ? offset ?
    434       1.8       mrg be*		at qec?
    435       1.8       mrg qe*		at qec?
    436       1.8       mrg 
    437       1.8       mrg # midway ATM
    438       1.8       mrg en0	at sbus? slot ? offset ?
    439       1.8       mrg 
    440       1.8       mrg # PCMCIA ethernet devices
    441       1.8       mrg #ep*	at pcmcia?
    442       1.8       mrg #mbe*	at pcmcia?
    443       1.8       mrg #ne*	at pcmcia?
    444       1.8       mrg #sm*	at pcmcia?
    445       1.8       mrg 
    446       1.8       mrg # MII/PHY support
    447       1.8       mrg #exphy*	at mii? phy ?			# 3Com internal PHYs
    448      1.30       wiz #icsphy*	at mii? phy ?			# Integrated Circuit Systems ICS189x
    449       1.8       mrg #inphy*	at mii? phy ?			# Intel 82555 PHYs
    450       1.8       mrg #lxtphy*	at mii? phy ?			# Level One LXT-970 PHYs
    451       1.8       mrg #nsphy*	at mii? phy ?			# NS83840 PHYs
    452       1.8       mrg #qsphy*	at mii? phy ?			# Quality Semiconductor QS6612 PHYs
    453       1.8       mrg #sqphy*	at mii? phy ?			# Seeq 80220/80221/80223 PHYs
    454       1.8       mrg #tlphy*	at mii? phy ?			# ThunderLAN PHYs
    455       1.8       mrg #ukphy*	at mii? phy ?			# generic unknown PHYs
    456       1.8       mrg 
    457       1.1       mrg ## Loopback network interface; required
    458       1.1       mrg pseudo-device	loop
    459       1.1       mrg 
    460       1.1       mrg ## SLIP and CSLIP interfaces, for IP over a serial line.
    461      1.54      cube #pseudo-device	sl		
    462       1.1       mrg 
    463       1.1       mrg ## PPP, the successor to SLIP.  See pppd(8).
    464      1.54      cube #pseudo-device	ppp		
    465       1.1       mrg 
    466       1.1       mrg ## Starmode Radio IP, a special hardware network device.
    467      1.54      cube #pseudo-device	strip		
    468       1.1       mrg 
    469       1.1       mrg ## Network "tunnel" device, allowing protocol stacks to run in the userland.
    470       1.1       mrg ## This is used by the third-party user-mode "ppp" program, and others.
    471      1.54      cube #pseudo-device	tun		
    472       1.1       mrg 
    473       1.8       mrg ## Generic L3 over IP tunnel
    474      1.54      cube #pseudo-device	gre			# generic L3 over IP tunnel
    475       1.8       mrg 
    476       1.1       mrg ## Berkeley Packet Filter, required to run RARPD.  A generic C-language
    477       1.1       mrg ## interface that allows selective examining of incoming packets.
    478      1.53    rpaulo #pseudo-device	bpfilter
    479       1.1       mrg 
    480  1.99.2.1  pgoyette #pseudo-device	npf			# NPF packet filter
    481       1.1       mrg 
    482       1.1       mrg #### Audio and video devices
    483       1.1       mrg 
    484       1.1       mrg ## /dev/audio support (`audioamd' plus `audio')
    485       1.1       mrg ##
    486       1.1       mrg #audioamd0	at mainbus0				# sun4c
    487       1.1       mrg #audioamd0	at obio0				# sun4m
    488       1.1       mrg #audioamd0	at sbus0 slot ? offset ?		# sun4m
    489       1.1       mrg #audio*		at audioamd0
    490       1.1       mrg 
    491       1.8       mrg #audiocs0	at sbus0 slot ? offset ?		# SUNW,CS4231
    492       1.8       mrg #audio*		at audiocs0
    493       1.8       mrg 
    494      1.95  christos #spkr*		at audio?		# PC speaker (synthesized)
    495      1.93       nat 
    496       1.1       mrg 
    497       1.1       mrg ## Sun "bwtwo" black and white framebuffer, found on sun4, sun4c, and sun4m
    498       1.1       mrg ## systems.  If your sun4 system has a cgfour installed in the P4 slot,
    499       1.1       mrg ## the P4 entries for "bwtwo" will attach to the overlay plane of the
    500       1.1       mrg ## "cgfour".
    501       1.1       mrg 
    502       1.1       mrg bwtwo0		at sbus0 slot ? offset ?		# sun4c and sun4m
    503       1.1       mrg bwtwo*		at sbus? slot ? offset ?		#
    504       1.1       mrg #bwtwo0		at obio0 addr 0xfd000000 level 4	# sun4/200
    505       1.1       mrg #bwtwo0		at obio0 addr 0xfb300000 level 4	# sun4/300 in P4 slot
    506       1.1       mrg #bwtwo0		at obio0 addr 0x0b300000 level 4	# sun4/100 in P4 slot
    507       1.1       mrg 
    508       1.1       mrg ## Sun "cgtwo" VME color framebuffer
    509      1.10  drochner #cgtwo0		at vme0 addr 0x400000 irq ? vect 0xa8
    510       1.1       mrg 
    511       1.1       mrg ## Sun "cgthree" Sbus color framebuffer
    512       1.1       mrg cgthree0	at sbus? slot ? offset ?
    513       1.1       mrg cgthree*	at sbus? slot ? offset ?
    514       1.1       mrg 
    515       1.1       mrg ## Sun "cgfour" color framebuffer with overlay plane.  See above comment
    516       1.1       mrg ## regarding overlay plane.
    517       1.1       mrg #cgfour0		at obio0 addr 0xfb300000 level 4	# sun4/300 P4
    518       1.1       mrg #cgfour0		at obio0 addr 0x0b300000 level 4	# sun4/100 P4
    519       1.1       mrg 
    520       1.1       mrg ## Sun "cgsix" accelerated color framebuffer.
    521       1.1       mrg cgsix0		at sbus? slot ? offset ?
    522       1.1       mrg cgsix*		at sbus? slot ? offset ?
    523       1.1       mrg #cgsix0		at obio0 addr 0xfb000000 level 4	# sun4/300 P4
    524       1.1       mrg #cgsix0		at obio0 addr 0x0b000000 level 4	# sun4/100 P4
    525       1.1       mrg 
    526       1.1       mrg ## Sun "cgeight" 24-bit framebuffer
    527       1.1       mrg #cgeight0 	at obio0 addr 0xfb300000 level 4	# sun4/300 P4
    528       1.1       mrg #cgeight0	at obio0 addr 0x0b300000 level 4	# sun4/100 P4
    529       1.1       mrg 
    530       1.1       mrg ## Sun "tcx" accelerated color framebuffer.
    531      1.70  macallan # there can be only one
    532      1.70  macallan tcx0		at sbus? slot ? offset ?
    533       1.1       mrg 
    534      1.74  macallan ## Sun CG12 / Matrox SG3 accelerated 24bit framebuffer
    535      1.74  macallan ## runs monochrome only for now
    536      1.74  macallan ## since it occupies 3 SBus slots there's no way to use more than one
    537      1.74  macallan cgtwelve0	at sbus? slot ? offset ?
    538      1.74  macallan 
    539       1.1       mrg # Sun "cgfourteen" accelerated 24-bit framebuffer.
    540      1.64  macallan cgfourteen*	at obio0			# sun4m
    541      1.64  macallan 
    542      1.64  macallan # P9100-based display on Tadpole SPARCbook 3.
    543      1.64  macallan pnozz0		at sbus? slot ? offset ?
    544      1.73  macallan # the SPARCbook 3 hardware docs say that accesses to P9100 registers need to be
    545      1.73  macallan # 'latched in' but at least my 3GX works happily without
    546      1.73  macallan # Enable it by default since we don't know which hardware really needs it.
    547      1.73  macallan options PNOZZ_USE_LATCH
    548      1.64  macallan 
    549      1.64  macallan # Sun ZX/Leo 24-bit framebuffer
    550      1.68  macallan zx*		at sbus? slot ? offset ?
    551       1.1       mrg 
    552      1.64  macallan # Fujitsu AG-10e accelerated graphics 8/24-bit board
    553      1.64  macallan agten*	at sbus? slot ? offset ?
    554      1.64  macallan 
    555      1.92  macallan ## Southland Media Systems (now Quantum 3D) MGX
    556      1.92  macallan mgx* 		at sbus? slot ? offset ?
    557      1.92  macallan 
    558      1.64  macallan # generic framebuffer console
    559      1.64  macallan genfb*	at sbus? slot ? offset ?
    560      1.64  macallan 
    561      1.64  macallan # make sure wsdisplay0 is the console
    562      1.64  macallan wsdisplay0	at wsemuldisplaydev? console 1
    563      1.64  macallan wsdisplay*	at wsemuldisplaydev?
    564       1.1       mrg 
    565       1.1       mrg #### Other device configuration
    566       1.1       mrg 
    567       1.1       mrg ## Pseudo ttys, required for network logins and programs like screen.
    568       1.1       mrg 
    569      1.86  christos pseudo-device	pty			# pseudo-terminals
    570       1.1       mrg 
    571       1.1       mrg ## Random device, used to implement /dev/random (a source of random noise),
    572       1.1       mrg ## and generate randomness for some kernel formulae.
    573       1.1       mrg 
    574      1.75     pooka #pseudo-device	fss			# file system snapshot device
    575      1.64  macallan 
    576      1.64  macallan pseudo-device	wsmux			# mouse and keyboard multiplexor
    577      1.64  macallan pseudo-device	wsfont
    578