Home | History | Annotate | Line # | Download | only in conf
      1 # $NetBSD: FOURMEG,v 1.64 2026/03/21 17:29:17 thorpej Exp $
      2 
      3 # FOURMEG Sun2 (2/120, 2/170, 2/50, ...)
      4 # Supports root on: ie0, sd*, ...
      5 
      6 include "arch/sun2/conf/std.sun2"
      7 
      8 #options 	INCLUDE_CONFIG_FILE	# embed config file in kernel binary
      9 
     10 #ident 		"FOURMEG-$Revision: 1.64 $"
     11 
     12 # Machines to be supported by this kernel
     13 #options 	FPU_EMULATE
     14 
     15 # Needs to be set per system.  i.e change these as you see fit
     16 maxusers	4
     17 
     18 # Standard system options
     19 #options 	KTRACE		# system call tracing
     20 #options 	SYSVMSG		# System V message queues
     21 #options 	SYSVSEM		# System V semaphores
     22 #options 	SYSVSHM		# System V shared memory
     23 #options 	INSECURE	# disable kernel security level
     24 #options 	USERCONF	# userconf(4) support
     25 options		PIPE_SOCKETPAIR	# smaller, but slower pipe(2)
     26 #options 	SYSCTL_INCLUDE_DESCR	# Include sysctl descriptions in kernel
     27 
     28 # Which kernel debugger?  Uncomment either this:
     29 #options 	DDB
     30 # ... or these for KGDB (gdb remote target)
     31 #makeoptions	DEBUG="-g"	# debugging symbols for gdb
     32 #options 	KGDB
     33 #options 	KGDB_DEV=0x0C00	# ttya=0C00 ttyb=0C01
     34 
     35 # Other debugging options
     36 #options 	DDB_HISTORY_SIZE=100	# enable history editing in DDB
     37 #options 	DEBUG		# kernel debugging code
     38 #options 	DIAGNOSTIC	# extra kernel sanity checking
     39 #options 	PMAP_DEBUG
     40 #options 	SCSIDEBUG
     41 #options 	SCSIVERBOSE		# Verbose SCSI errors
     42 
     43 # Compatibility options
     44 #include 	"conf/compat_netbsd16.config"
     45 #options 	COMPAT_SUNOS	# can run SunOS 4.1.1 executables
     46 #options 	COMPAT_AOUT_M68K # support for NetBSD a.out executables
     47 #options 	EXEC_AOUT	# support for a.out executables
     48 
     49 # Filesystem options
     50 file-system	FFS		# Berkeley Fast Filesystem
     51 file-system	NFS		# Sun NFS client support
     52 file-system	CD9660		# ISO 9660 + Rock Ridge file system
     53 #file-system	FDESC		# /dev/fd/*
     54 #file-system	KERNFS		# /kern
     55 #file-system	NULLFS		# loopback file system
     56 #file-system	OVERLAY		# overlay file system
     57 #file-system	PROCFS		# /proc
     58 #file-system	UNION		# union file system
     59 #file-system	MFS		# memory-based filesystem
     60 #file-system	PTYFS		# /dev/pts/N support
     61 
     62 #options 	NFSSERVER	# nfs server support
     63 #options 	QUOTA		# legacy UFS quotas
     64 #options 	QUOTA2		# new, in-filesystem UFS quotas
     65 #options 	FFS_EI		# FFS Endian Independent support
     66 #options 	NFS_V2_ONLY	# Exclude NFS3 code to save space
     67 options 	FFS_NO_SNAPSHOT	# No FFS snapshot support
     68 
     69 # Networking options
     70 options 	INET		# IP protocol stack support
     71 #options 	INET6		# IPV6
     72 #options 	IPSEC		# IP security
     73 #options 	IPSEC_DEBUG	# debug for IP security
     74 #options 	GATEWAY		# IP packet forwarding
     75 #options 	TCP_DEBUG	# Record last TCP_NDEBUG packets with SO_DEBUG
     76 
     77 # Work-around for root on slow servers (insurance...)
     78 options 	NFS_BOOT_RWSIZE=1024
     79 options 	NFS_BOOT_BOOTPARAM
     80 
     81 config		netbsd root on ? type ?
     82 
     83 #### Main bus.
     84 mainbus0 at root
     85 
     86 #### Bus types.
     87 
     88 obio0	at mainbus? 		# all Sun-2
     89 obmem0	at mainbus?		# all Sun-2
     90 mbmem0	at mainbus?		# 2/120, 2/170
     91 mbio0	at mainbus?		# 2/120, 2/170
     92 sun68kvme0	at mainbus?	# 2/50, 2/130, 2/160
     93 vme0	at sun68kvme0		# mi VME attachment
     94 
     95 #### Standard system devices.
     96 
     97 ## The AM9513 clock chip.
     98 clock0	at obio0 addr 0x002800	# 2/120, 2/170
     99 clock0	at obio0 addr 0x7f2800	# 2/50, 2/130, 2/160
    100 
    101 ## The MM58167 time-of-day chip.
    102 tod0	at obio0 addr 0x003800	# 2/120, 2/170
    103 tod0	at vme0 addr 0x200800	# 2/50, 2/130, 2/160
    104 
    105 #### Serial port configuration.
    106 
    107 ## Zilog 8530 serial chips.  Each has two channels.
    108 ## zs0 is ttya and ttyb.  zs1 is the keyboard and mouse.
    109 ## zs0 is REQUIRED to use KGDB.
    110 zs0	at obio0 addr 0x002000	# 2/120, 2/170
    111 zs0	at obio0 addr 0x7f2000	# 2/50
    112 zs1	at obmem0 addr 0x780000	# 2/120, 2/170
    113 zs1	at obio0 addr 0x7f1800	# 2/50
    114 zs2	at mbmem0 addr 0x080800	# 2/120, 2/170 (first sc SCSI)
    115 zs3	at mbmem0 addr 0x081000	# 2/120, 2/170 (first sc SCSI)
    116 zs4	at mbmem0 addr 0x084800	# 2/120, 2/170 (second sc SCSI)
    117 zs5	at mbmem0 addr 0x085000	# 2/120, 2/170 (second sc SCSI)
    118 zstty*	at zs? channel ?	# ttya
    119 kbd0	at zstty?		# keyboard
    120 ms0	at zstty?		# mouse
    121 
    122 #### Disk controllers and disks.
    123 
    124 ## PAL+logic-based "Sun SCSI 2" Multibus/VME SCSI controller.
    125 ## This driver has several flags which may be enabled using
    126 ## the "flags" directive.  Valid flags are:
    127 ##
    128 ## 0x0ff		Set (1<<target) to disable parity checking
    129 ## 0x100		Set this bit to disable DMA interrupts (poll)
    130 ## 0x200		Set this bit to disable DMA entirely (use PIO)
    131 ##
    132 ## For example: "flags 0x10f" would disable DMA interrupts,
    133 ## and disable parity for targets 0-3
    134 
    135 sc0	at mbmem0 addr 0x80000 ipl 2 flags 0xff
    136 sc0	at vme0 addr 0x200000 irq 2 vect 0x40 flags 0xff
    137 sc1	at mbmem0 addr 0x84000 ipl 2 flags 0xff
    138 
    139 ## NCR5380-based "Sun SCSI 3" VME SCSI controller.
    140 ## This driver has several flags which may be enabled by OR'ing
    141 ## the values and using the "flags" directive.
    142 ## Valid flags are:
    143 ##
    144 ##	0x01		Use DMA (may be polled)
    145 ##	0x02		Use DMA completion interrupts
    146 ##	0x04		Allow disconnect/reselect
    147 ##
    148 ## E.g. the following would enable DMA, interrupts, and reselect:
    149 ## si0	at vme0 addr 0x200000 ipl 3 vect 0x40 flags 0x07
    150 ##
    151 ## By default, DMA is enabled in the driver.
    152 
    153 si0	at vme0 addr 0x200000 irq 2 vect 0x40
    154 
    155 ## These entries find devices on all SCSI busses and assign
    156 ## unit numbers dynamically.
    157 scsibus* at sc?
    158 scsibus* at si?
    159 sd*	at scsibus? target ? lun ?		# SCSI disks
    160 st*	at scsibus? target ? lun ?		# SCSI tapes
    161 cd*	at scsibus? target ? lun ?		# SCSI CD-ROMs
    162 #ch*	at scsibus? target ? lun ?		# SCSI changer devices
    163 #ss*	at scsibus? target ? lun ?		# SCSI scanners
    164 #ses*	at scsibus? target ? lun ?		# SCSI SES/SAF-TE
    165 #uk*	at scsibus? target ? lun ?		# unknown SCSI
    166 
    167 # support old SCSI devices that don't understand the INQUIRY command
    168 options 	SCSI_OLD_NOINQUIRY
    169 
    170 ## Xylogics 450 or 451 Multibus/VME SMD disk controllers and disks.
    171 #xyc0	at mbio0 addr 0xee40 ipl 2
    172 #xyc0	at vme0 addr 0xee40 irq 2 vect 0x48
    173 #xyc1	at mbio0 addr 0xee48 ipl 2
    174 #xyc1	at vme0 addr 0xee48 irq 2 vect 0x49
    175 #xy*	at xyc? drive ?
    176 
    177 ## Memory-disk device.
    178 pseudo-device	md		
    179 
    180 #### Network interfaces.
    181 
    182 ## Intel Ethernet (onboard, or Multibus/VME)
    183 ie0	at obio0 addr 0x7f0800 ipl 3		# 2/50
    184 ie0	at mbmem0 addr 0x88000 ipl 3
    185 ie1	at mbmem0 addr 0x8c000 ipl 3
    186 ## VME: the first [addr,len] pair specifies the device registers;
    187 ##	the second pair specifies the on-board memory buffer
    188 ie1	at vme0 addr 0xe88000,0xe00000 len -1,0x40000 irq 3 vect 0x75
    189 
    190 ## 3Com Ethernet (Multibus only)
    191 ec0	at mbmem0 addr 0xe0000 ipl 3
    192 ec1	at mbmem0 addr 0xe2000 ipl 3
    193 # limit NFS R/W size for poor ec(4) interfaces
    194 options 	NFS_RSIZE=1024,NFS_WSIZE=1024
    195 
    196 ## Frame buffers.
    197 
    198 ## Sun "bwtwo" black and white framebuffer.
    199 bwtwo0	at obmem0 addr 0x700000	# 2/120, 2/170
    200 bwtwo0	at obio0 addr 0x0	# 2/50
    201 
    202 ## PROM console driver -- if all else fails
    203 pcons0	at mainbus0			# PROM console
    204 
    205 #### Miscellaneous.
    206 pseudo-device	loop			# network loopback
    207 #pseudo-device	bpfilter		# packet filter
    208 #pseudo-device	sl			# CSLIP
    209 #pseudo-device	ppp			# PPP
    210 #pseudo-device	tun			# network tunneling over tty
    211 #pseudo-device	gre			# generic L3 over IP tunnel
    212 #pseudo-device	npf			# NPF packet filter
    213 #pseudo-device	gif			# IPv[46] over IPv[46] tunnel (RFC1933)
    214 #pseudo-device	faith			# IPv[46] tcp relay translation i/f
    215 #pseudo-device	stf			# 6to4 IPv6 over IPv4 encapsulation
    216 
    217 pseudo-device	pty			# pseudo-terminals
    218 #pseudo-device	vnd			# paging to files
    219 #pseudo-device	ccd			# concatenated disks
    220 #pseudo-device	raid			# RAIDframe disk driver
    221 #options 	RAID_AUTOCONFIG		# auto-configuration of RAID components
    222 #pseudo-device	fss			# file system snapshot device
    223 pseudo-device	clockctl		# user control of clock subsystem
    224 
    225 no options AIO
    226 no options BUFQ_FCFS
    227 no options RFC2292
    228 no options MQUEUE
    229