Home | History | Annotate | Line # | Download | only in conf
RAMDISK revision 1.3
      1 # $NetBSD: RAMDISK,v 1.3 2001/06/27 16:51:21 fredette Exp $
      2 
      3 # RAMDISK: Root/swap on ramdisk
      4 # This kernel is used to:
      5 #      format the disk (not yet implemented)
      6 #      partition the disk (disklabel)
      7 #      install the miniroot in the swap partition
      8 
      9 # GENERIC Sun2 (2/120, 2/170, 2/50, ...)
     10 # Supports root on: ie0, sd*, ...
     11 
     12 include "arch/sun2/conf/std.sun2"
     13 
     14 # Machines to be supported by this kernel
     15 #options 	FPU_EMULATE
     16 
     17 # Needs to be set per system.  i.e change these as you see fit
     18 maxusers	2
     19 
     20 # Standard system options
     21 #options 	KTRACE		# system call tracing
     22 #options 	SYSVMSG		# System V message queues
     23 #options 	SYSVSEM		# System V semaphores
     24 #options 	SYSVSHM		# System V shared memory
     25 #options 	SHMMAXPGS=1024	# 1024 pages is the default
     26 #options 	LKM		# loadable kernel modules
     27 #options 	INSECURE	# disable kernel security level
     28 #options 	UCONSOLE	# Allow non-root TIOCCONS
     29 
     30 # Which kernel debugger?  Uncomment either this:
     31 #options 	DDB
     32 # ... or these for KGDB (gdb remote target)
     33 #makeoptions DEBUG="-g"		# debugging symbols for gdb
     34 #options 	KGDB
     35 #options 	KGDBDEV=0x0C00	# ttya=0C00 ttyb=0C01
     36 
     37 # Other debugging options
     38 #options 	DDB_HISTORY_SIZE=100	# enable history editing in DDB
     39 #options 	DEBUG		# kernel debugging code
     40 #options 	DIAGNOSTIC	# extra kernel sanity checking
     41 #options 	KMEMSTATS	# kernel memory statistics (vmstat -m)
     42 #options 	PMAP_DEBUG
     43 #options 	SCSIDEBUG
     44 #options 	SCSIVERBOSE		# Verbose SCSI errors
     45 
     46 # Compatibility options
     47 #options 	COMPAT_SUNOS	# can run SunOS 4.1.1 executables
     48 #options 	COMPAT_43	# and 4.3BSD and ...
     49 options		COMPAT_AOUT_M68K # support for NetBSD a.out executables
     50 options		EXEC_AOUT	# support for a.out executables
     51 
     52 # Filesystem options
     53 file-system	FFS		# Berkeley Fast Filesystem
     54 file-system	NFS		# Sun NFS client support
     55 file-system	CD9660		# ISO 9660 + Rock Ridge file system
     56 #file-system	FDESC		# /dev/fd/*
     57 #file-system	KERNFS		# /kern
     58 #file-system	NULLFS		# loopback file system
     59 #file-system	OVERLAY		# overlay file system
     60 #file-system	PROCFS		# /proc
     61 #file-system	UNION		# union file system
     62 #file-system	MFS		# memory-based filesystem
     63 
     64 #options 	NFSSERVER	# nfs server support
     65 #options 	QUOTA		# FFS quotas
     66 options 	FFS_EI		# FFS Endian Independant support
     67 #options 	SOFTDEP         # FFS soft updates support.
     68 
     69 # Networking options
     70 options 	INET		# IP prototol stack support
     71 #options 	INET6		# IPV6
     72 #options 	IPSEC		# IP security
     73 #options 	IPSEC_ESP	# IP security (encryption part; define w/IPSEC)
     74 #options 	IPSEC_DEBUG	# debug for IP security
     75 options 	TCP_COMPAT_42	# compatibility with 4.2BSD TCP/IP
     76 #options 	GATEWAY		# IP packet forwarding
     77 #options 	ISO,TPIP	# OSI networking
     78 #options 	EON		# OSI tunneling over IP
     79 #options 	CCITT,LLC,HDLC	# X.25
     80 #options 	PFIL_HOOKS	# pfil(9) packet filter hooks.
     81 
     82 # Work-around for root on slow servers (insurance...)
     83 #options 	NFS_BOOT_RWSIZE=1024
     84 #options 	NFS_BOOT_BOOTPARAM
     85 
     86 # Enable the hooks used for initializing the root memory-disk.
     87 options		MEMORY_DISK_HOOKS
     88 options		MEMORY_DISK_IS_ROOT	# force root on memory disk
     89 options		MEMORY_DISK_SERVER=0	# no userspace memory disk support
     90 options		MINIROOTSIZE=800	# size of memory disk, in blocks
     91 
     92 config		netbsd root on ? type ffs
     93 
     94 #### Main bus.
     95 mainbus0 at root
     96 
     97 #### Bus types.
     98 
     99 obio0	at mainbus? 		# all Sun-2
    100 obmem0	at mainbus?		# all Sun-2
    101 mbmem0	at mainbus?		# 2/120, 2/170
    102 mbio0	at mainbus?		# 2/120, 2/170
    103 sun68kvme0	at mainbus?	# 2/50, 2/130, 2/160
    104 vme0	at sun68kvme0		# mi VME attachment
    105 
    106 #### Standard system devices.
    107 
    108 ## The AM9513 clock chip.
    109 clock0  at obio0 addr 0x002800	# 2/120, 2/170
    110 clock0  at obio0 addr 0x7f2800	# 2/50, 2/130, 2/160
    111 
    112 ## The MM58167 time-of-day chip.
    113 tod0    at obio0 addr 0x003800	# 2/120, 2/170
    114 tod0	at vme0 addr 0x200800	# 2/50, 2/130, 2/160
    115 
    116 #### Serial port configuration.
    117 
    118 ## Zilog 8530 serial chips.  Each has two channels.
    119 ## zs0 is ttya and ttyb.  zs1 is the keyboard and mouse.
    120 ## zs0 is REQUIRED to use KGDB.
    121 zs0	at obio0 addr 0x002000	# 2/120, 2/170
    122 zs0	at obio0 addr 0x7f2000	# 2/50
    123 zs1	at obmem0 addr 0x780000	# 2/120, 2/170
    124 zs1	at obio0 addr 0x7f1800	# 2/50
    125 zs2	at mbmem0 addr 0x080800	# 2/120, 2/170 (first sc SCSI)
    126 zs3	at mbmem0 addr 0x081000	# 2/120, 2/170 (first sc SCSI)
    127 zs4	at mbmem0 addr 0x084800	# 2/120, 2/170 (second sc SCSI)
    128 zs5	at mbmem0 addr 0x085000	# 2/120, 2/170 (second sc SCSI)
    129 zstty*	at zs? channel ?	# ttya
    130 kbd0	at zstty?		# keyboard
    131 #ms0	at zstty?		# mouse
    132 
    133 #### Disk controllers and disks.
    134 
    135 ## PAL+logic-based "Sun SCSI 2" Multibus/VME SCSI controller.
    136 ## This driver has several flags which may be enabled using
    137 ## the "flags" directive.  Valid flags are:
    138 ##
    139 ## 0x0ff		Set (1<<target) to disable parity checking
    140 ## 0x100		Set this bit to disable DMA interrupts (poll)
    141 ## 0x200		Set this bit to disable DMA entirely (use PIO)
    142 ##
    143 ## For example: "flags 0x10f" would disable DMA interrupts,
    144 ## and disable parity for targets 0-3
    145 
    146 sc0	at mbmem0 addr 0x80000 ipl 2 flags 0xff
    147 sc0 at vme0  addr 0x200000 irq 2 vect 0x40 flags 0xff
    148 sc1	at mbmem0 addr 0x84000 ipl 2 flags 0xff
    149 
    150 ## NCR5380-based "Sun SCSI 3" VME SCSI controller.
    151 ## This driver has several flags which may be enabled by OR'ing
    152 ## the values and using the "flags" directive.
    153 ## Valid flags are:
    154 ##
    155 ##	0x01		Use DMA (may be polled)
    156 ##	0x02		Use DMA completion interrupts
    157 ##	0x04		Allow disconnect/reselect
    158 ##
    159 ## E.g. the following would enable DMA, interrupts, and reselect:
    160 ## si0	at vme0 addr 0x200000 ipl 3 vect 0x40 flags 0x07
    161 ##
    162 ## By default, DMA is enabled in the driver.
    163 
    164 si0	at vme0 addr 0x200000 irq 2 vect 0x40
    165 
    166 ## These entries find devices on all SCSI busses and assign
    167 ## unit numbers dynamically.
    168 scsibus* at sc?
    169 scsibus* at si?
    170 sd*	at scsibus? target ? lun ?		# SCSI disks
    171 st*	at scsibus? target ? lun ?		# SCSI tapes
    172 cd*	at scsibus? target ? lun ?		# SCSI CD-ROMs
    173 #ch*	at scsibus? target ? lun ?		# SCSI changer devices
    174 #ss*	at scsibus? target ? lun ?		# SCSI scanners
    175 #ses*	at scsibus? target ? lun ?		# SCSI SES/SAF-TE
    176 #uk*	at scsibus? target ? lun ?		# unknown SCSI
    177 
    178 ## Xylogics 450 or 451 Multibus/VME SMD disk controllers and disks.
    179 #xyc0	at mbio0 addr 0xee40 ipl 2 
    180 xyc0	at vme0 addr 0xee40 irq 2 vect 0x48
    181 #xyc1	at mbio0 addr 0xee48 ipl 2 
    182 xyc1	at vme0 addr 0xee48 irq 2 vect 0x49
    183 xy*	at xyc? drive ?
    184 
    185 ## Memory-disk device.
    186 pseudo-device	md		2
    187 
    188 #### Network interfaces.
    189 
    190 ## Intel Ethernet (onboard, or Multibus/VME)
    191 ie0	at obio0 addr 0x7f0800 ipl 3		# 2/50
    192 ie0	at mbmem0 addr 0x88000 ipl 3
    193 ie1	at mbmem0 addr 0x8c000 ipl 3
    194 ## VME: the first [addr,len] pair specifies the device registers;
    195 ##	the second pair specifies the on-board memory buffer
    196 ie1	at vme0 addr 0xe88000,0xe00000 len -1,0x40000 irq 3 vect 0x75
    197 
    198 ## 3Com Ethernet (Multibus only)
    199 ec0	at mbmem0 addr 0xe0000 ipl 3
    200 ec1	at mbmem0 addr 0xe2000 ipl 3
    201 
    202 ## Frame buffers.
    203 
    204 ## Sun "bwtwo" black and white framebuffer.
    205 #bwtwo0  at obmem0 addr 0x700000	# 2/120, 2/170
    206 #bwtwo0	at obio0 addr 0x0	# 2/50
    207 
    208 ## PROM console driver -- if all else fails
    209 pcons0	at mainbus0			# PROM console
    210 
    211 #### Miscellaneous.
    212 pseudo-device	loop		1	# network loopback
    213 #pseudo-device	bpfilter	8	# packet filter
    214 pseudo-device	sl		2	# CSLIP
    215 #pseudo-device	ppp		2	# PPP
    216 #pseudo-device	tun		2	# network tunneling over tty
    217 #pseudo-device	gre		2	# generic L3 over IP tunnel
    218 #pseudo-device	ipfilter		# ip filter
    219 #pseudo-device	gif		4	# IPv[46] over IPv[46] tunnel (RFC1933)
    220 #pseudo-device	faith		1	# IPv[46] tcp relay translation i/f
    221 #pseudo-device	stf		1	# 6to4 IPv6 over IPv4 encapsulation
    222 # rnd is EXPERIMENTAL
    223 #pseudo-device	rnd			# /dev/random and in-kernel generator
    224 
    225 #pseudo-device	pty		32	# pseudo-terminals
    226 #pseudo-device	vnd		4	# paging to files
    227 #pseudo-device	ccd		4	# concatenated disks
    228 #pseudo-device	raid		4	# RAIDframe disk driver
    229 #options 	RAID_AUTOCONFIG		# auto-configuration of RAID components
    230