GENERIC revision 1.101 1 # $NetBSD: GENERIC,v 1.101 2003/09/22 14:11:29 cl Exp $
2 #
3 # GENERIC machine description file
4 #
5 # This machine description file is used to generate the default NetBSD
6 # kernel. The generic kernel does not include all options, subsystems
7 # and device drivers, but should be useful for most applications.
8 #
9 # The machine description file can be customised for your specific
10 # machine to reduce the kernel size and improve its performance.
11 #
12 # For further information on compiling NetBSD kernels, see the config(8)
13 # man page.
14 #
15 # For further information on hardware support for this architecture, see
16 # the intro(4) man page. For further information about kernel options
17 # for this architecture, see the options(4) man page. For an explanation
18 # of each device driver in this file see the section 4 man page for the
19 # device.
20
21 # Supports Sun3 (3/50, 3/60, 3/110, 3/160, 3/260, 3/E)
22 # Supports root on: ie0, le0, sd*, ...
23
24 include "arch/sun3/conf/std.sun3"
25
26 options INCLUDE_CONFIG_FILE # embed config file in kernel binary
27
28 #ident "GENERIC-$Revision: 1.101 $"
29
30 # Machines to be supported by this kernel
31 options FPU_EMULATE
32 options HAVECACHE # Sun3/260 VAC
33
34 # Needs to be set per system. i.e change these as you see fit
35 maxusers 4
36
37 # Standard system options
38 options KTRACE # system call tracing
39 options SYSTRACE # system call vetting via systrace(1)
40 options SYSVMSG # System V message queues
41 options SYSVSEM # System V semaphores
42 #options SEMMNI=10 # number of semaphore identifiers
43 #options SEMMNS=60 # number of semaphores in system
44 #options SEMUME=10 # max number of undo entries per process
45 #options SEMMNU=30 # number of undo structures in system
46 options SYSVSHM # System V shared memory
47 #options SHMMAXPGS=1024 # 1024 pages is the default
48 options LKM # loadable kernel modules
49 #options INSECURE # disable kernel security level
50 options USERCONF # userconf(4) support
51 #options PIPE_SOCKETPAIR # smaller, but slower pipe(2)
52
53 # Enable experimental buffer queue strategy for better responsiveness under
54 # high disk I/O load. Use it with caution - it's not proven to be stable yet.
55 #options NEW_BUFQ_STRATEGY
56
57 # Which kernel debugger? Uncomment either this:
58 options DDB
59 # ... or these for KGDB (gdb remote target)
60 #makeoptions DEBUG="-g" # debugging symbols for gdb
61 #options KGDB
62 #options KGDB_DEV=0x0C01 # ttya=0C00 ttyb=0C01
63
64 # Other debugging options
65 #options DDB_HISTORY_SIZE=100 # enable history editing in DDB
66 #options DEBUG # kernel debugging code
67 #options DIAGNOSTIC # extra kernel sanity checking
68 #options KMEMSTATS # kernel memory statistics (vmstat -m)
69 #options PMAP_DEBUG
70 #options SCSIDEBUG
71 #options SCSIVERBOSE # Verbose SCSI errors
72
73 # Compatibility options
74 options COMPAT_SUNOS # can run SunOS 4.1.1 executables
75 #options COMPAT_SVR4 # can run SVR4 executables
76 options COMPAT_43 # and 4.3BSD and ...
77 options COMPAT_10 # NetBSD 1.0
78 options COMPAT_11 # NetBSD 1.1
79 options COMPAT_12 # NetBSD 1.2
80 options COMPAT_13 # NetBSD 1.3
81 options COMPAT_14 # NetBSD 1.4
82 options COMPAT_15 # NetBSD 1.5
83 options COMPAT_16 # NetBSD 1.6
84 options COMPAT_AOUT_M68K # support for NetBSD a.out executables
85 #options COMPAT_LINUX # can run Linux/m68k executables
86 options EXEC_AOUT # support for a.out executables
87 #options TCP_COMPAT_42 # 4.2BSD TCP/IP bug compat. Not recommended.
88
89 # Filesystem options
90 file-system FFS # Berkeley Fast Filesystem
91 file-system NFS # Sun NFS client support
92 file-system CD9660 # ISO 9660 + Rock Ridge file system
93 file-system FDESC # /dev/fd/*
94 file-system KERNFS # /kern
95 file-system NULLFS # loopback file system
96 file-system OVERLAY # overlay file system
97 file-system PROCFS # /proc
98 file-system UNION # union file system
99 file-system MFS # memory-based filesystem
100
101 options NFSSERVER # nfs server support
102 options QUOTA # FFS quotas
103 #options FFS_EI # FFS Endian Independant support
104 options SOFTDEP # FFS soft updates support.
105
106 # Networking options
107 options INET # IP prototol stack support
108 options INET6 # IPV6
109 #options IPSEC # IP security
110 #options IPSEC_ESP # IP security (encryption part; define w/IPSEC)
111 #options IPSEC_DEBUG # debug for IP security
112 #options GATEWAY # IP packet forwarding
113 #options ISO,TPIP # OSI networking
114 #options EON # OSI tunneling over IP
115 #options CCITT,LLC,HDLC # X.25
116 options PFIL_HOOKS # pfil(9) packet filter hooks.
117 #options TCP_DEBUG # Record last TCP_NDEBUG packets with SO_DEBUG
118
119 # Work-around for root on slow servers (insurance...)
120 options NFS_BOOT_RWSIZE=1024
121 options NFS_BOOT_BOOTPARAM
122
123 config netbsd root on ? type ?
124
125 # On-board I/O space (required)
126 include "arch/sun3/conf/obio.sun3"
127
128 # On-board memory (optional)
129 # See frame-buffers
130 obmem0 at mainbus?
131
132 # VME bus support (optional)
133 # One unit for each address space
134 vme0 at mainbus? # A16/D16
135 vme1 at mainbus? # A16/D32
136 vme2 at mainbus? # A24/D16
137 vme3 at mainbus? # A24/D32
138 vme4 at mainbus? # A32/D16
139 vme5 at mainbus? # A32/D32
140
141 #
142 # Serial ports
143 #
144 zstty0 at zsc1 channel 0 # ttya
145 zstty1 at zsc1 channel 1 # ttyb
146
147 kbd0 at zsc0 channel 0 # keyboard
148 ms0 at zsc0 channel 1 # mouse
149
150 #
151 # Network devices
152 #
153
154 # Intel Ethernet (onboard, or VME)
155 ie0 at obio0 addr 0x0C0000 ipl 3
156 ie1 at vme2 addr 0xe88000 ipl 3 vect 0x75
157
158 # Lance Ethernet (only onboard)
159 le0 at obio0 addr 0x120000 ipl 3
160
161 # All Sun3 machines with an "le" (3/50, 3/60) should be
162 # presumed to have the old, buggy LANCE chip. (Rev. C)
163 options LANCE_REVC_BUG
164
165 #
166 # Disk and tape devices
167 #
168
169 # Sun3 "si" SCSI controller (NCR 5380)
170 # This driver has several flags which may be enabled using
171 # the "flags" directive. Valid flags are:
172 #
173 # 0x000ff Set (1<<target) to disable disconnect/reselect
174 # 0x0ff00 Set (1<<(target+8)) to disable parity checking
175 # 0x10000 Set this bit to disable DMA interrupts (poll)
176 # 0x20000 Set this bit to disable DMA entirely (use PIO)
177 #
178 # For example: "flags 0x1000f" would disable DMA interrupts,
179 # and disable disconnect/reselect for targets 0-3
180 si0 at obio0 addr 0x140000 ipl 2
181 si0 at vme2 addr 0x200000 ipl 2 vect 0x40
182 si1 at vme2 addr 0x204000 ipl 2 vect 0x41
183
184 # Xylogics 450/451 controllers (VME A16/D16)
185 xyc0 at vme0 addr 0xee40 ipl 2 vect 0x48
186 xyc1 at vme0 addr 0xee48 ipl 2 vect 0x49
187 xy* at xyc? drive ?
188
189 # Xylogics 7053 controllers (VME A16/D32)
190 xdc0 at vme1 addr 0xee80 ipl 2 vect 0x44
191 xdc1 at vme1 addr 0xee90 ipl 2 vect 0x45
192 xd* at xdc? drive ?
193
194 # Xylogics 472 tape controllers?
195
196 # Sun3/E SCSI+Ethernet board (VME A24/D16)
197 # Note: the board uses vect and vect+1
198 sebuf0 at vme2 addr 0x300000 ipl 2 vect 0x74 # and 0x75
199 sebuf1 at vme2 addr 0x340000 ipl 2 vect 0x76 # and 0x77
200 si* at sebuf?
201 ie* at sebuf?
202
203 #
204 # Frame buffer devices
205 #
206
207 include "arch/sun3/conf/bw2.sun3"
208 include "arch/sun3/conf/cg4.sun3"
209
210 # 3/60 P4 accelerated 8-bit color frame buffer
211 # cgsix0 at obmem0 addr 0xff000000
212
213 # 3/60 P4 24-bit color frame buffer
214 # cgeight0 at obmem0 addr 0xff300000
215
216 # Sun-3 color board, or CG5 8-bit frame buffer (VME A24/D16).
217 cgtwo0 at vme2 addr 0x400000 ipl 4 vect 0xA8
218
219 # Support for the CG9 24-bit frame buffer (VME A32/D32).
220 # cgnine0 at vme5 addr 0x08000000 ipl 4 vect 0xAA
221
222 #
223 # SCSI infrastructure
224 #
225 scsibus* at scsi?
226
227 sd* at scsibus? target ? lun ? # SCSI disks
228 st* at scsibus? target ? lun ? # SCSI tapes
229 cd* at scsibus? target ? lun ? # SCSI CD-ROMs
230 ch* at scsibus? target ? lun ? # SCSI changer devices
231 ss* at scsibus? target ? lun ? # SCSI scanners
232 uk* at scsibus? target ? lun ? # unknown SCSI devices
233
234 # Memory-disk drivers
235 pseudo-device md 2
236
237 # Misc.
238 pseudo-device loop 1 # network loopback
239 pseudo-device bpfilter 8 # packet filter
240 pseudo-device sl 2 # CSLIP
241 pseudo-device ppp 2 # PPP
242 pseudo-device pppoe # PPP over Ethernet (RFC 2516)
243 pseudo-device tun 2 # network tunneling over tty
244 #pseudo-device gre 2 # generic L3 over IP tunnel
245 #pseudo-device ipfilter # ip filter
246 pseudo-device gif 4 # IPv[46] over IPv[46] tunnel (RFC1933)
247 #pseudo-device faith 1 # IPv[46] tcp relay translation i/f
248 #pseudo-device stf 1 # 6to4 IPv6 over IPv4 encapsulation
249 pseudo-device vlan # IEEE 802.1q encapsulation
250 pseudo-device bridge # simple inter-network bridging
251 #options BRIDGE_IPF # bridge uses IP/IPv6 pfil hooks too
252 pseudo-device rnd # /dev/random and in-kernel generator
253
254 pseudo-device pty # pseudo-terminals
255 pseudo-device vnd 4 # paging to files
256 #pseudo-device ccd 4 # concatenated disks
257 #pseudo-device cgd 4 # cryptographic disk devices
258 #pseudo-device raid 4 # RAIDframe disk driver
259 #options RAID_AUTOCONFIG # auto-configuration of RAID components
260 # Options to enable various other RAIDframe RAID types.
261 # options RF_INCLUDE_EVENODD=1
262 # options RF_INCLUDE_RAID5_RS=1
263 # options RF_INCLUDE_PARITYLOGGING=1
264 # options RF_INCLUDE_CHAINDECLUSTER=1
265 # options RF_INCLUDE_INTERDECLUSTER=1
266 # options RF_INCLUDE_PARITY_DECLUSTERING=1
267 # options RF_INCLUDE_PARITY_DECLUSTERING_DS=1
268 pseudo-device clockctl # user control of clock subsystem
269 pseudo-device ksyms # /dev/ksyms
270