GENERIC revision 1.49 1 # $NetBSD: GENERIC,v 1.49 1998/02/05 04:56:26 gwr Exp $
2
3 # GENERIC Sun3 (3/50, 3/60, 3/110, 3/160, 3/260, 3/E)
4 # Supports root on: ie0, le0, sd*, ...
5
6 include "arch/sun3/conf/std.sun3"
7
8 # Machines to be supported by this kernel. Note:
9 # The SUN3 and SUN3X options are mutually exclusive!
10 # (Your kernel will only run on one or the other.)
11 makeoptions MACHTYPE=sun3
12 options _SUN3_
13
14 options FPU_EMULATE
15 options HAVECACHE # Sun3/260 VAC
16
17 # Needs to be set per system. i.e change these as you see fit
18 maxusers 4
19
20 # Standard system options
21 options KTRACE # system call tracing
22 options SYSVMSG # System V message queues
23 options SYSVSEM # System V semaphores
24 options SYSVSHM # System V shared memory
25 #options SHMMAXPGS=1024 # 1024 pages is the default
26 #options LKM # loadable kernel modules
27 #options INSECURE # disable kernel security level
28 #options UCONSOLE # Allow non-root TIOCCONS
29
30 # Which kernel debugger? Uncomment either this:
31 options DDB
32 # ... or these for KGDB (gdb remote target)
33 #makeoptions DEBUG="-g" # debugging symbols for gdb
34 #options KGDB
35 #options KGDBDEV=0x0C01 # ttya=0C00 ttyb=0C01
36
37 # Other debugging options
38 #options DDB_HISTORY_SIZE=100 # enable history editing in DDB
39 #options DEBUG # kernel debugging code
40 #options DIAGNOSTIC # extra kernel sanity checking
41 #options KMEMSTATS # kernel memory statistics (vmstat -m)
42 #options PMAP_DEBUG
43 #options SCSIDEBUG
44 #options SCSIVERBOSE # Verbose SCSI errors
45
46 # Compatability options
47 options COMPAT_SUNOS # can run SunOS 4.1.1 executables
48 options COMPAT_43 # and 4.3BSD and ...
49 options COMPAT_10 # NetBSD 1.0
50 options COMPAT_11 # NetBSD 1.1
51 options COMPAT_12 # NetBSD 1.2
52 options COMPAT_13 # NetBSD 1.3
53
54 # Filesystem options
55 file-system FFS # Berkeley Fast Filesystem
56 file-system NFS # Sun NFS client support
57 file-system CD9660 # ISO 9660 + Rock Ridge file system
58 file-system FDESC # /dev/fd/*
59 file-system KERNFS # /kern
60 file-system NULLFS # loopback file system
61 file-system PROCFS # /proc
62 file-system UNION # union file system
63 file-system MFS # memory-based filesystem
64
65 options FIFO # FIFOs; RECOMMENDED
66 options NFSSERVER # nfs server support
67 options QUOTA # FFS quotas
68
69 # Networking options
70 options INET # IP prototol stack support
71 options TCP_COMPAT_42 # compatibility with 4.2BSD TCP/IP
72 #options GATEWAY # IP packet forwarding
73 #options ISO,TPIP # OSI networking
74 #options EON # OSI tunneling over IP
75 #options CCITT,LLC,HDLC # X.25
76 #options PFIL_HOOKS # pfil(9) packet filter hooks.
77
78 # Work-around for root on slow servers (insurance...)
79 options NFS_BOOT_RWSIZE=1024
80 options NFS_BOOT_BOOTPARAM
81
82 config netbsd root on ? type ?
83
84 # On-board I/O space (required)
85 include "arch/sun3/conf/obio.sun3"
86
87 # On-board memory (optional)
88 # See frame-buffers
89 obmem0 at mainbus?
90
91 # VME bus support (optional)
92 # One unit for each address space
93 vme0 at mainbus? # A16/D16
94 vme1 at mainbus? # A16/D32
95 vme2 at mainbus? # A24/D16
96 vme3 at mainbus? # A24/D32
97 vme4 at mainbus? # A32/D16
98 vme5 at mainbus? # A32/D32
99
100 #
101 # Serial ports
102 #
103 zstty0 at zsc1 channel 0 # ttya
104 zstty1 at zsc1 channel 1 # ttyb
105
106 kbd0 at zsc0 channel 0 # keyboard
107 ms0 at zsc0 channel 1 # mouse
108
109 #
110 # Network devices
111 #
112
113 # Intel Ethernet (onboard, or VME)
114 ie0 at obio0 addr 0x0C0000 ipl 3
115 ie1 at vme2 addr 0xe88000 ipl 3 vect 0x75
116
117 # Lance Ethernet (only onboard)
118 le0 at obio0 addr 0x120000 ipl 3
119
120 # All Sun3 machines with an "le" (3/50, 3/60) should be
121 # presumed to have the old, buggy LANCE chip. (Rev. C)
122 options LANCE_REVC_BUG
123
124 #
125 # Disk and tape devices
126 #
127
128 # Sun3 "si" SCSI controller (NCR 5380)
129 # This driver has several flags which may be enabled using
130 # the "flags" directive. Valid flags are:
131 #
132 # 0x000ff Set (1<<target) to disable disconnect/reselect
133 # 0x0ff00 Set (1<<(target+8)) to disable parity checking
134 # 0x10000 Set this bit to disable DMA interrupts (poll)
135 # 0x20000 Set this bit to disable DMA entirely (use PIO)
136 #
137 # For example: "flags 0x1000f" would disable DMA interrupts,
138 # and disable disconnect/reselect for targets 0-3
139 si0 at obio0 addr 0x140000 ipl 2
140 si0 at vme2 addr 0x200000 ipl 2 vect 0x40
141 si1 at vme2 addr 0x204000 ipl 2 vect 0x41
142
143 # Xylogics 450/451 controllers (VME A16/D16)
144 xyc0 at vme0 addr 0xee40 ipl 2 vect 0x48
145 xyc1 at vme0 addr 0xee48 ipl 2 vect 0x49
146 xy* at xyc? drive ?
147
148 # Xylogics 7053 controllers (VME A16/D32)
149 xdc0 at vme1 addr 0xee80 ipl 2 vect 0x44
150 xdc1 at vme1 addr 0xee90 ipl 2 vect 0x45
151 xd* at xdc? drive ?
152
153 # Xylogics 472 tape controllers?
154
155 # Sun3/E SCSI+Ethernet board (VME A24/D16)
156 # Note: the board uses vect and vect+1
157 sebuf0 at vme2 addr 0x300000 ipl 2 vect 0x74 # and 0x75
158 sebuf1 at vme2 addr 0x340000 ipl 2 vect 0x76 # and 0x77
159 si* at sebuf?
160 ie* at sebuf?
161
162 #
163 # Frame buffer devices
164 #
165
166 # The default cgfour address depends on the machine:
167 # 3/60: obmem 0xFF200000 .. 0xFF9fffff
168 # 3/110: different? (not tested)
169 cgfour0 at obmem0 addr ?
170
171 # 3/60 P4 accelerated 8-bit color frame buffer
172 # cgsix0 at obmem0 addr ?
173
174 # 3/60 P4 24-bit color frame buffer
175 # cgeight0 at obmem0 addr ?
176
177 # The default bwtwo address depends on the machine:
178 # 3/50: obmem 0x100000
179 # else: obmem 0xff000000
180 bwtwo0 at obmem0 addr ?
181 # 3/60 P4 color frame buffer overlay plane, or P4 monochrome frame buffer
182 #bwtwo1 at obmem0 addr 0xff300000
183 # 3/60 plug-in color frame buffer overlay plane
184 #bwtwo1 at obmem0 addr 0xff400000
185
186 # Sun-3 color board, or CG5 8-bit frame buffer (VME A24/D16).
187 cgtwo0 at vme2 addr 0x400000 ipl 4 vect 0xA8
188
189 # Support for the CG9 24-bit frame buffer (VME A32/D32).
190 # cgnine0 at vme5 addr 0x08000000 ipl 4 vect 0xAA
191
192 #
193 # SCSI infrastructure
194 #
195 scsibus* at scsi?
196
197 sd* at scsibus? target ? lun ? # SCSI disks
198 st* at scsibus? target ? lun ? # SCSI tapes
199 cd* at scsibus? target ? lun ? # SCSI CD-ROMs
200 ch* at scsibus? target ? lun ? # SCSI changer devices
201 ss* at scsibus? target ? lun ? # SCSI scanners
202 uk* at scsibus? target ? lun ? # unknown SCSI devices
203
204 # Memory-disk drivers
205 pseudo-device md 2
206
207 # Misc.
208 pseudo-device loop 1 # network loopback
209 pseudo-device bpfilter 8 # packet filter
210 pseudo-device sl 2 # CSLIP
211 pseudo-device ppp 2 # PPP
212 pseudo-device tun 2 # network tunneling over tty
213 #pseudo-device ipfilter # ip filter
214 # rnd is EXPERIMENTAL
215 #pseudo-device rnd # /dev/random and in-kernel generator
216
217 pseudo-device pty 32 # pseudo-terminals
218 #pseudo-device vnd 4 # paging to files
219 #pseudo-device ccd 4 # concatenated disks
220